LV850011

Reverse Power Protection

Trade Price

£601.08

Per

1

Unit

EA

Pack Quantity

1

LV850011

Information

This is the digital module "ANSI 32P - Reverse active power" for Micrologic X trip unit on MasterPact MTZ offer. A digital module is an advanced function that can be uploaded in Micrologic X trip unit at any stage of the product life cycle. Digital modules allow you to customize MasterPact MTZ circuit breaker to your specific needs. The digital modules are available 24/7 on the Schneider Electric GoDigital store (godigital.schneider-electric.com). The upload of the digital modules is made without interrupting power, using EcoStruxure Power Commission software and a USB cable. This digital module allows to trip the circuit breaker when the active power is negative and exceeds the settings. The reverse active power protection requires the Micrologic X control unit to be supplied by an external 24 V dc power supply. The Micrologic X control unit firmware (greater than or equal to V002.000.xxx) is compatible with this digital module. Earlier firmware versions need to be upgraded. The benefit is to monitor the mode of operation of a synchronous power generator connected to an external network or running in parallel with other generators. It causes tripping as soon as the generator operates as a synchronous motor, driving its prime mover. It also monitors the active power exchange between separate parts of an electrical network.

Technical Specifications

Range

MasterPact

Product or component type

Application

Application description

Reverse active power ANSI 32P

Range compatibility

MasterPact MTZ1 circuit breaker MasterPact MTZ2 circuit breaker MasterPact MTZ3 circuit breaker

Product compatibility

control unit MicroLogic 2.0 X control unit MicroLogic 3.0 X control unit MicroLogic 5.0 X control unit MicroLogic 6.0 X control unit MicroLogic 7.0 X control unit MicroLogic 2.0 Xi control unit MicroLogic 3.0 Xi control unit MicroLogic 5.0 Xi control unit MicroLogic 6.0 Xi control unit MicroLogic 7.0 Xi

function of module

Protection

Service description

Circuit breaker trips when the active power is negative and exceeds the settings Reverse active power protection monitors the active power

Service benefits

Tripping as soon as the generator operates as a synchronous motor Monitoring of the mode of operation of a synchronous power generator Monitoring of active power exchanged between separate parts of an installation

Energy management

Network management (option)

Protection type

Reverse active power ANSI code: 32P (option)

Software name

EcoStruxure Power Commission

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

0.3 cm

Package 1 Width

0.2 cm

Package 1 Length

0.3 cm

Package 1 Weight

0.01 kg

Warranty

18 months

Document Links

Catalogue page

Datasheet