Range of produc
Lexium integrated drive
Product or component type
Motion integrated drive
Device short name
ILS
Motor type
3-phase stepper motor
Number of motor poles
6
Network number of phases
Single phase
[Us] rated supply voltage
24 V 36 V
Network type
DC
Communication interface
Pulse/direction 24 V, integrated
Length
138.9 mm
Winding type
Medium speed of rotation and medium torque
Electrical connection
Printed circuit board connector
Holding brake
Without
Gear box type
Without
Nominal speed
200 rpm at 24 V 500 rpm at 36 V
Nominal torque
1.5 N.m
Holding torque
1.7 N.m
mounting support
Flange
Motor flange size
57 mm
Number of motor stacks
3
Centring collar diameter
38.1 mm
Centring collar depth
1.6 mm
Number of mounting holes
4
Mounting holes diameter
5.2 mm
Circle diameter of the mounting holes
66.6 mm
Feedback type
Index pulse
Shaft end
Untapped
Second shaft
Without second shaft end
Shaft diameter
8 mm
Shaft length
21 mm
Supply voltage limits
18…40 V
Current consumption
3500 mA maximum continuous
Associated fuse rating
10 A
input/output type
4 signals (each be used as input or output)
Voltage state 0 guaranteed
-3...4.5 V
Voltage state 1 guaranteed
15...30 V
Discrete input current
10 mA at 24 V for safety input
Discrete output voltage
23...25 V
Maximum switching current
100 mA per output 200 mA total
Protection type
Short circuit of the output voltage Overload of output voltage Safe torque off
Peak stall torque
1.5 N.m
Continuous stall torque
1.5 N.m
Speed feedback resolution
1.8°, 0.9°, 0.72°, 0.36°, 0.18°, 0.09°, 0.072°, 0.036° 200, 400, 500, 1000, 2000, 4000, 5000, 10000 steps
accuracy error
+/- 6 arc min
Rotor inertia
0.38 kg.cm²
Maximum mechanical speed
3000 rpm
Maximum radial force Fr
50 N
Maximum axial force Fa
100 N (tensile force) 8.4 N (force pressure)
Service life in hours
20000 h bearing
Marking
CE
Type of cooling
Natural convection
Net weight
2 kg
Standards
EN 61800-3 : 2001-02 IEC 50347 IEC 61800-3 IEC 60072-1 IEC 50178 IEC 61800-3, Ed 2 EN 61800-3:2001, second environment
product certifications
cUL TÜV UL
Ambient air temperature for operation
50…65 °C (with power derating of 2 % per °C) 0…50 °C (without derating)
Permissible ambient air temperature around the device
105 °C power amplifier 110 °C motor
Ambient air temperature for storage
-25…70 °C
Operating altitude
<= 1000 m without derating
Relative humidity
15…85 % without condensation
Vibration resistance
20 m/s² (f= 10…500 Hz) 10 cycles conforming to IEC 60068-2-6
Shock resistance
150 m/s² 1000 shocks conforming to IEC 60068-2-29
IP degree of protection
IP41 shaft bushing: conforming to IEC 60034-5 IP54 total except shaft bushing: conforming to IEC 60034-5
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
10.5 cm
Package 1 Width
17 cm
Package 1 Length
24.5 cm
Package 1 Weight
2.129 kg
Unit Type of Package 2
S04
Number of Units in Package 2
6
Package 2 Height
30 cm
Package 2 Width
40 cm
Package 2 Length
60 cm
Package 2 Weight
14.026 kg
Unit Type of Package 3
S06
Number of Units in Package 3
30
Package 3 Height
73.5 cm
Package 3 Width
60 cm
Package 3 Length
80 cm
Package 3 Weight
97 kg
Warranty
18 months