Trade Price
£232.21
Per
1
Unit
EA
Pack Quantity
1
Canalis tap-off unit for KT and KS. It's applied to medium power distribution and TT, IT and TN-S earthing system. The operational voltage is from 230VAC 50/60Hz to 690VAC 50/60Hz. The rated operational current is 50A at 35 ℃. Mounting by Plug-in with fixed polarity with white RAL 9001 surface treatment and whose busbar trunking polarity is 3L+N+PE. It provided protection for size 14 x 51 fuses (Fuse to be ordered separately). It provided tap-off unit disconnection by right opening the door. Canalis KS busbar trunking compatibility with plug-in outlets, Canalis KT busbar trunking compatibility with KS type plug-in outlets. It provides IP55 protection which conforming to IEC 60529 standard. IK08 conforms to IEC 62262. It is compliant with both IEC 61439-1 and IEC 61439-6. It is also compliant with Green Premium (RoHS/REACH).
Range of product
Canalis
Range compatibility
Canalis (KT) busbar trunking Canalis (KS) busbar trunking
Product or component type
Tap-off unit
busbar trunking compatibility
Canalis KS busbar trunkingplug-in Canalis KT busbar trunking with KS type plug-in
[Ie] rated operational current
50 A at 35 °C
protection type
fuse isolator: for aM cylindrical fuse, size 14 x 51 mm - 50 A conforming to NF fuse isolator: for gG cylindrical fuse, size 14 x 51 mm - 50 A conforming to NF
Provided equipment
fuse to be ordered separately
Mounting mode
Plug-in with fixed polarity
Tap-off unit polarity
3L+N+PE
Colour
White (RAL 9001)
Device application
Medium power distribution
[Ue] rated operational voltage
230...690 V depending on protective device
[Uimp] rated impulse withstand voltage
6.8 kV
[Ui] rated insulation voltage
500 V depending on protective device
Network frequency
50/60 Hz
Electrical connection
Cable clamp terminal - ISO50 25 mm² flexible Cable clamp terminal - ISO50 25 mm² rigid
door/cover opening side
Right
Tap-off unit disconnection mode
By opening the door
Standards
IEC 61439-1 IEC 61439-6
body material
Plastic
Width
356 mm
Depth
103 mm
depth (door open)
432.5 mm
height
202 mm
Net weight
2.4 kg
Earthing system
TT TN-S IT
IP degree of protection
IP55 conforming to IEC 60529
IK degree of protection
IK08 conforming to IEC 62262
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
17.000 cm
Package 1 Width
22.500 cm
Package 1 Length
37.000 cm
Package 1 Weight
2.136 kg
Unit Type of Package 2
P12
Number of Units in Package 2
38
Package 2 Height
80.000 cm
Package 2 Width
80.000 cm
Package 2 Length
120.000 cm
Package 2 Weight
99.000 kg
Warranty
18 months
Datasheet