Trade Price
£2,109.09
Per
1
Unit
EA
Pack Quantity
1
Range of product
Easergy P3
Product or component type
Protection relay
Relay application
Universal
product reference
P3U30-6AAA3BCAA
power supply
48...230 V AC/DC
measuring inputs
: 1/5 A CT phase current 3 : 1/5 A CT residual current 1 : 100 V/110 V VT voltage 4
number of Digital Inputs (DI)
16
number of Digital Outputs (DO)
1 watchdog 8
number of analogue outputs
0
communication ports
USB port 1 front RJ45 2 rear
communication protocols
IEC 61850 ed. 1 IEC 61850 ed. 2 IEC 60870-5-101 DNP3 TCP Modbus TCP EtherNet/IP
Redundancy communication port protocol
RSTP PRP
Cybersecurity
Password protection Port hardening
protection functions
Phase overcurrent 50/51 Directional phase overcurrent 67 Earth fault overcurrent 50N/51N Directional earth fault 67N Transient earth fault 67NI Capacitor bank unbalance 51C Broken conductor 46 I2/I1 Cold load pick-up Switch ON to fault (SOTF) Breaker failure 50BF Directional active underpower 37P Fault locator 21FL Recloser 79 Phase undercurrent 37 Excessive starting time, locked rotor 48/51LR Motor restart inhibition 66 Capacitor overvoltage 59C Negative sequence overcurrent 46 Overvoltage 59 Undervoltage 27 Positive sequence undervoltage 27P Earth fault overvoltage 59N Underfrequency 81/81N Rate of change of frequency 81R Synchro-check 25 Lockout relay 86 CT supervision 60 VT supervision 60 H2 detection 68H2 H5 detection 68H5 Negative sequence overcurrent 47 Programmable stages 99 Programmable curve
Arc flash protection
No
measurement functions
Current 3-phase Current zero sequence Current positive sequence Current negative sequence Current ratio of negative and positive Voltage phase to earth Voltage phase to phase Voltage zero sequence Voltage positive sequence Voltage negative sequence Voltage ratio of negative and positive Short circuit fault reactance Fault location current Earth fault reactance Frequency Active power RMS active power Reactive power RMS reactive power Apparent power RMS apparent power Active energy Reactive energy Cos φ Tan φ Power angle Power factor Voltage phasor diagram view Current phasor diagram view Current 2nd, 15th harmonics with THD Voltage 2nd, 15th harmonics with THD Voltage interruption Condition monitoring CB wear
control functions
Switchgear control and monitoring Programmable switchgear interlocking Local control on single-line diagram Local control with I/O keys Local/remote control 2 function keys Mobile application with Easergy SmartApp Web-server Programmable logic
controllable switchgear devices
4 controlled + 8 displayed
number of setting groups
4
monitoring functions
Trip circuit supervision 74 Circuit breaker monitoring Relay self-monitoring
logs and records
Event recording Disturbance recording Tripping context
Switchgear diagnosis type
CT/VT supervision ANSI code: 60 CT supervision Trip circuit supervision ANSI code: TCS
Connections - terminals
Screw removable (digital input/output) Ring lugs removable (current transformer) Pin removable (voltage transformer)
Operating threshold
220...230 V AC/DC
Time synchronisation protocol
SNTP
Web server
Embedded HTTP server
Software name
EcoStruxure Power Device ESetup Easergy Pro
Display type
LCD 128 x 64 pixels with single line diagram
Number of key
2 customizable
Local signalling
4 LEDs 8 LEDs programmable
Standards
IEC
Height
169.5 mm
Width
170 mm
Depth
205 mm
Net weight
2.5 kg maximum
Electromagnetic compatibility
Emission tests conforming to IEC/EN 60255-26 ed. 3 Emission tests class A conforming to CISPR 11 Emission tests class A conforming to CISPR 22 EMC immunity conforming to IEC/EN 60255-26 ed. 3 EMC immunity conforming to EN/IEC 61000-4-18 EMC immunity level 4 conforming to EN/IEC 61000-4-2 EMC immunity level 3 conforming to EN/IEC 61000-4-3 EMC immunity level 4 conforming to EN/IEC 61000-4-4 EMC immunity level 3 conforming to EN/IEC 61000-4-5 EMC immunity level 3 conforming to EN/IEC 61000-4-6 EMC immunity conforming to EN/IEC 61000-4-8 EMC immunity level 5 conforming to EN/IEC 61000-4-9 EMC immunity conforming to EN/IEC 61000-4-29 EMC immunity conforming to EN/IEC 61000-4-11 EMC immunity conforming to EN/IEC 61000-4-17
Mechanical robustness
Vibrations (level: class II) conforming to IEC 60255-21-1 Vibrations: Fc conforming to IEC 60068-2-6 Shocks (level: class II) conforming to IEC 60255-21-2 Shocks: Ea conforming to IEC 60068-2-27 Seismic tests method A (level: class II) conforming to IEC 60255-21-3 Bumps (level: class II) conforming to IEC 60255-21-2 Bumps: Ea conforming to IEC 60068-2-27
climatic withstand
Exposure to dry heat Bb tests conforming to EN/IEC 60068-2-2 Exposure to cold Ad tests conforming to EN/IEC 60068-2-1 Exposure to damp heat in service Db tests conforming to EN/IEC 60068-2-30 Exposure to damp heat in service Cab tests conforming to EN/IEC 60068-2-78
Ambient air temperature for operation
-40…65 °C
Relative humidity
0…95 %, without condensation
maximum operating altitude
2000 m
Protective treatment
Conformal coating
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
30 cm
Package 1 Width
29.9 cm
Package 1 Length
39.8 cm
Package 1 Weight
3.84 kg
Unit Type of Package 2
P06
Number of Units in Package 2
8
Package 2 Height
105 cm
Package 2 Width
60 cm
Package 2 Length
80 cm
Package 2 Weight
43.46 kg
Warranty
Up to 10 years extended warranty (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)