Information

The PowerLogic P5 is Schneider Electric's withdrawable protection and control relay for demanding medium voltage distribution applications. This motor relay offers withdrawable design with backup memory function enabling industry-leading 10 minute recovery time. It provides redundant Ethernet including IEC 61850 as well as plug and play communication modules that can evolve with your application. The product embeds latest cybersecurity functionality to help prevent intentional mis-use and cyber-threats. PowerLogic P5 offers safety, security, and connectivity built on more than 100 years of experience in protection relays. The PowerLogic P5 protection relay can be applied to all types of MV distribution networks. It can be supplied with 48 to 250 VDC and 100 to 230 VAC. It works with conventional CTs/VTs. 3 phase current inputs, 1 Schneider Electric specific CSH neutral current input and 4 voltage inputs. It offers 16 digital inputs and 12 digital outputs, Ethernet RSTP RJ45 module with Dual IP and backup memory module. The product dimensions are 180 mm in height (7.09 in), 152,4 mm in width (6.00 in) and 224 mm in depth 8.82 in) for a net weight of 3.5 kg (7.7 lbs). PowerLogic P5 is compliant with EN 60255-26, EN 60255-27 standard and with UL Standard. It provides Marine certification. This product can be flush mounted on the panel or in the rack. Flush mounting frames to ensure IP54 are available. Fixing and wiring accessories are included. Plug and play communication modules: Ethernet RSTP RJ45 (REL51038), Ethernet RSTP FO (REL51039), Ethernet HSR/PRP FO (REL51033). And also 2nd Ethernet RSTP RJ45 (REL51042), RS485 serial RJ45 (REL51036), RS485 serial FO (REL51040), Extension/backup memory (REL51034). IP54 flush mounting frame (REL51052), CSH core-balance CTs (59635, 59636, 59637), 8 temperature sensor module (59641), IRIG-B module (REL51045). connection cords (59660, 59661, 59662). eSetup Easergy Pro software with virtual injection testing and EcoStruxure Power Device app for simpler and safer operation and maintenance. Included with functions as per the datasheet below. For other configurations with additional functions and options, Please select via Product Selector.

Technical Specifications

Range of product

PowerLogic P5

Product or component type

Protection relay

Relay application

Motor

product reference

P5M30-BACB-HABAH-AAAA

Mounting case size

30TE

Device mounting

Flush

Mounting mode

Withdrawable

power supply

48...250 V DC 100...230 V AC

measuring inputs

: 1/5 A CT phase current 3 : CSH residual current 1 : VT voltage 4

number of Digital Inputs (DI)

16

number of Digital Outputs (DO)

11 DO 1 watchdog

number of analogue outputs

0

communication ports

RJ45 2 rear Extension port 1 rear with backup memory USB port 2 front

communication protocols

IEC 61850 ed. 1 IEC 61850 ed. 2 DNP3 over ethernet Modbus TCP EtherNet/IP

Redundancy communication port protocol

RSTP

Cybersecurity

Password protection Port hardening Firmware signature Client IP address filter Secured communication with assciated tools

protection functions

Phase overcurrent 50/51 Directional phase overcurrent 67 Earth fault overcurrent 50N/51N Directional earth fault 67N Transient earth fault 67NI Neutral admittance 21YN Earth fault wattmetric 32N Broken conductor 46 I2/I1 Current unbalance 46 I2/I1 Cold load pick-up Switch ON to fault (SOTF) H2 detection H5 detection Breaker failure 50BF Directional active underpower 37P Phase undercurrent 37 Excessive starting time, locked rotor 48/51LR Motor restart inhibition 66 Negative sequence overcurrent 46 Overvoltage 59 Undervoltage 27 Positive sequence undervoltage 27P Earth fault overvoltage 59N Underfrequency 81/81N Lockout relay 86 CT supervision 60 VT supervision 60 Programmable stages 99 Programmable logic Programmable curve

measurement functions

Current 3-phase Current zero sequence Current positive sequence Current negative sequence Current ratio of negative and positive Phasor diagram of currents or voltages Current 2nd, 15th harmonics with THD Voltage 3-phase Voltage residual Voltage zero sequence Voltage positive sequence Voltage negative sequence Frequency

control functions

Switchgear control and monitoring Programmable switchgear interlocking Local/remote control

controllable switchgear devices

6 controlled + 2 monitored objects

number of setting groups

4

monitoring functions

Trip circuit supervision 74 Circuit breaker monitoring Relay self-monitoring

logs and records

Event recording Disturbance recording Tripping context Relay maintenance

Switchgear diagnosis type

CT/VT supervision ANSI code: 60 Trip circuit supervision ANSI code: 74

Connections - terminals

Screw (digital input/output) Ring lugs (analog inputs and outputs)

Time synchronisation protocol

SNTP

Web server

Embedded HTTP server

Software name

EcoStruxure Power Device ESetup Easergy Pro: virtual simulation test

Display type

and colour LCD 480 x 272 pixels

Number of key

7 customizable

Local signalling

4 x LED 10 x LED tri-colour programmable

Height

176 mm

Width

152 mm

Depth

219 mm

Net weight

3.5 kg

Electromagnetic compatibility

Emission tests class A conforming to CISPR 11 Emission tests class A conforming to CISPR 22 Emission tests conforming to IACS E10 EMC immunity class 4 conforming to IEC 61000-4-2 EMC immunity class 4 conforming to ANSI C37.90.3 EMC immunity level 3 conforming to IEC 61000-4-3 EMC immunity conforming to ANSI C37.90.2 EMC immunity conforming to GOST 32137 EMC immunity conforming to GOST 30804.4.3 EMC immunity conforming to IACS E10 EMC immunity level 5 conforming to IEC 61000-4-8 EMC immunity level 5 conforming to IEC 61000-4-9 EMC immunity level 5 conforming to IEC 61000-4-10 EMC immunity level 3 conforming to IEC 61000-4-6 EMC immunity level 3 conforming to IEC 61000-4-18 EMC immunity conforming to ANSI C37.90.1 EMC immunity conforming to IEC 61000-4-12 EMC immunity conforming to GOST 30804.4.12 EMC immunity level 4 conforming to IEC 61000-4-16 EMC immunity level 4 conforming to IEC 61000-4-4 EMC immunity level 4 conforming to IEC 61000-4-5

Mechanical robustness

Vibrations (level: class 2) conforming to IEC 60255-21-1 Vibrations conforming to GOST 17516.1 Vibrations conforming to IACS E10 Shocks (level: class 2) conforming to IEC 60255-21-2 Earthquakes (level: class 2) conforming to IEC 60255-21-3

climatic withstand

Exposure to cold conforming to IEC 60068-2-1 Exposure to dry heat conforming to IEC 60068-2-2 Exposure to damp heat in service conforming to IEC 60068-2-78 Exposure to damp heat in service conforming to IEC 60068-2-30 Temperature variation conforming to IEC 60068-2-14 Salt mist conforming to IEC 60068-2-52 Influence of corrosion/gas test 2 conforming to IEC 60068-2-60 Influence of corrosion/gas test 4 conforming to IEC 60068-2-60 Influence of corrosion/gas test 2 conforming to IEC 60721-3-3 Influence of corrosion/gas test 4 conforming to IEC 60721-3-3

Ambient air temperature for operation

-40…85 °C ( 16 h ) -40…70 °C ( 96 h )

Relative humidity

0…93 % at 40 °C, without condensation, 56 days 93…95 % at 25…55 °C, 6 cycles, 12 + 12 hours

maximum operating altitude

2000 m

Protective treatment

Conformal coating conforming to IEC 60068-2-52:Kb/1 Conformal coating conforming to IEC 60068-2-60:Ke Conformal coating conforming to IEC 60721-3-3:3C2

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

30.0 cm

Package 1 Width

30.0 cm

Package 1 Length

35.0 cm

Package 1 Weight

4.5 kg

Warranty

Up to 10 years extended warranty (Standard warranty 2 years. Please check with your local SE representative for extended warranty availability and conditions)

Document Links

Datasheet