METSEPM3255

Power meter Modbus with memory

Trade Price

£553.90

Per

1

Unit

EA

Pack Quantity

1

METSEPM3255
METSEPM3255
METSEPM3255

Information

PM3255 DIN mount energy meter with a 128 by 96 pixel backlit, LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor, Apparent Power, Total Harmonic Distortion and up to 15th Harmonic. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 100 to 277VAC, 173 to 480VAC and 100 to 300VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase, Single Phase and Neutral or Three Phase configurations. Direct measurement range is 50 to 570VAC, with an external VT 570 to 999000VAC. The range of measurement voltage between Phases is 80 to 570VAC at 45 to 65 Hz. Measurement range between Phase and Neutral is 50 to 330VAC at 45 to 65 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. Support for two digital input and two digital outputs. The meter offers 512kB of memory for event recording with up to 15 alarms with power and energy consumption logs. Product dimensions are as follows: width 3.54 in (90 mm), depth 2.76in (70 mm), height 3.74 in (95 mm) and product weight 9.17 oz (260 g).

Technical Specifications

Range

PowerLogic

Product name

PowerLogic PM3000

Device short name

PM3255

Product or component type

Power meter

Power quality analysis

up to the 15th harmonic

Device application

Multi-tariff Power monitoring Sub billing

Type of measurement

Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U)

supply voltage

100...277 V AC 45...65 Hz 173...480 V AC 45...65 Hz 100...300 V DC

Network frequency

60 Hz 50 Hz

[In] rated current

5 A 1 A

type of network

3P 3P + N 1P + N

Power consumption in VA

5 VA

Display type

Backlit LCD

Display resolution

128 x 96 pixels

Sampling rate

32 samples/cycle

Measurement current

0.02…1.2 A 0.05…6 A

Analogue input type

Current 0...5 A Current 0...1 A

Measurement voltage

50…330 V AC 45...65 Hz direct 50…330 V AC 45...65 Hz phase to neutral 80…570 V AC 45...65 Hz direct 80…570 V AC 45...65 Hz phase to phase 570…999000 V AC 45...65 Hz with external VT

Frequency measurement range

45…65 Hz

Number of inputs

2 digital 0...4 mA 11...40 V DC

Measurement accuracy

Current 0.3 % 0.5...6 A Current 0.5 % 0.1...1.2 A Voltage 0.3 % 50...330 V Voltage 0.3 % 80...570 V

Accuracy class

Class 0.5S active energy conforming to IEC 62053-22 Class 1 active energy conforming to IEC 62053-21 Class 2 reactive energy conforming to IEC 62053-23 Class C active energy conforming to EN 50470-3

Number of outputs

2 digital (static)

Information displayed

Tariff (4)

Communication port protocol

Modbus at 9.6...38.4 kbauds

Communication port support

RS485

data recording

Energy consumption logs 15 alarms Power logs Time stamping Min/max of instantaneous values

Memory capacity

512 KB

Mounting mode

Clip-on

Mounting support

DIN rail

standards

BS EN 61557-12 IEC 61557-12 EN 61557-12 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11 IEC 62052-11 EN 62052-11 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22 IEC 62053-22 EN 62052-22 BS EN 62053-23 IEC 62053-23 EN 62052-23 BS EN 61010-1 EN 61010-1 IEC 61010-1 UL 61010-1 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20

Product certifications

CE conforming to IEC 61010-1 (safety) CE conforming to EN 61557-12 (power monitor) CE conforming to EN/IEC 61326-1 (EMC) UKCA conforming to BS EN 61010-1 (safety) UKCA conforming to BS EN 61557-12 (power monitor) UKCA conforming to BS EN 61326-1 (EMC) CULus conforming to EN 61010-1 (safety) CULus conforming to UL 61010-1 (safety) EAC (sub-meter) RCM

Width

90 mm

Depth

70 mm

height

95 mm

Net weight

0.26 kg

Electromagnetic compatibility

Electrostatic discharge level 4 conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Surge immunity test level 4 conforming to IEC 61000-4-5 Conducted RF disturbances level 3 conforming to IEC 61000-4-6 Magnetic field at power frequency - test level: 0.5 mT conforming to IEC 61000-4-8 Conducted and radiated emissions class B conforming to EN 55022

Overvoltage category

III

IP degree of protection

IP40 front panel: conforming to IEC 60529 IP20 body: conforming to IEC 60529

Relative humidity

5…95 % at 50 °C

Pollution degree

2

Ambient air temperature for operation

-25…70 °C

Ambient air temperature for storage

-40…85 °C

Operating altitude

< 3000 m

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

13.5 cm

Package 1 Width

13.5 cm

Package 1 Length

9.0 cm

Package 1 Weight

410.0 g

Unit Type of Package 2

S03

Number of Units in Package 2

16

Package 2 Height

30.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

7.036 kg

Unit Type of Package 3

P12

Number of Units in Package 3

384

Package 3 Height

95.0 cm

Package 3 Width

80.0 cm

Package 3 Length

120.0 cm

Package 3 Weight

177.864 kg

Warranty

18 months

Document Links