VLS1P040R1S

1 AUX POLE 40A

Trade Price

£42.29

Per

1

Unit

EA

Pack Quantity

1

VLS1P040R1S

Information

These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This fourth pole adder can be added to a VLS3P016R1, VLS3P025R1, VLS3P032R1 or VLS3P040R1 DIN rail mount switch. This fourth pole adder for DIN rail mounted devices can be mounted on the right or left hand side. This simultaneous closing adder pole has one normally open contact The operational voltage of this fourth pole adder module is 600 Vac 50/60 Hz. This fourth pole adder module has a 40 A current rating. The screw clamp terminals will accept 18 AWG to 6 AWG wire. Fourth pole adder is 3.07 inches tall, 0.47 inches wide and 1.72 inches deep. It weighs 0.09 lbs. This fourth pole adder block is cULus Listed and meets IEC 60947-3 requirements.

Technical Specifications

Range

TeSys

Device short name

VLS1P

Product or component type

Additional pole

Performance level

High performance

Poles description

1P

Contacts type and composition

1 NO

contact operation

Simultaneous

Range compatibility

TeSys (TeSys VARIO LS) VLS3P

Network type

AC

Network frequency

50/60 Hz

Suitability for isolation

Yes

Mounting location

Left Right

mounting support

DIN rail

[Ue] rated operational voltage

690 V AC 50/60 Hz

[Uimp] rated impulse withstand voltage

8 kV

[Ith] conventional free air thermal current

40 A (at 55 °C)

[Ithe] conventional enclosed thermal current

40 A

[Ie] rated operational current

40 A Ue: 600 V conforming to UL 508 40 A AC-21A Ue: 400 V 40 A AC-21A Ue: 500 V 40 A AC-21A Ue: 690 V 40 A AC-22A Ue: 400 V 40 A AC-22A Ue: 500 V 40 A AC-22A Ue: 690 V 40 A AC-23A Ue: 400 V 25 A AC-23A Ue: 500 V 25 A AC-23A Ue: 690 V

Rated operational power in W

18.5 kW at 400 V (AC-23A) 18.5 kW at 500 V (AC-23A) 22 kW at 690 V (AC-23A)

Intermittent duty class

Class 120 - 60 %

Making capacity ( I Rms)

60 A at 690 V AC-21A 120 A at 690 V AC-22A 400 A at 690 V AC-23A

[Icm] rated short-circuit making capacity

1128 A at 690 V

[Icw] rated short-time withstand Rms current

800 A at 690 V duration: 1 s

Rated conditional short-circuit current

50 kA at 400 V - associated fuse 40 A gG

Breaking capacity

60 A at 690 V (AC-21A) 120 A at 690 V (AC-22A) 320 A at 690 V (AC-23A)

Mechanical durability

100000 cycles

Electrical durability

100000 cycles AC-21A

Connections - terminals

Power circuit: screw clamp terminals10 mm² - solid Power circuit: screw clamp terminals16 mm² - flexible - without cable end

Tightening torque

Power circuit: 1.8…2 N.m - on screw clamp terminals

height

78 mm

Width

12 mm

Depth

43.6 mm

Net weight

0.04 kg

Colour

Grey

standards

UL 508 CSA C22.2 No 14 IEC 60947-3

product certifications

cULus GL

IP degree of protection

IP20 conforming to IEC 60529

Mechanical robustness

Vibrations 2...100 Hz Fc (0.7 g) conforming to IEC 60068-2-6 Shocks 11 ms Ea (15 gn) conforming to IEC 60068-2-27

Ambient air temperature for operation

-25…55 °C

Fire resistance

960 °C conforming to IEC 60695-2-11

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

7.8 cm

Package 1 Width

4.4 cm

Package 1 Length

1.2 cm

Package 1 Weight

43 g

Unit Type of Package 2

S01

Number of Units in Package 2

30

Package 2 Height

15 cm

Package 2 Width

15 cm

Package 2 Length

40 cm

Package 2 Weight

1.515 kg

Warranty

18 months

Document Links

Datasheet