Trade Price
£42.60
Per
1
Unit
EA
Pack Quantity
24
TeSys D contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). It provides a 24V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Pack of 10 units. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Range
TeSys TeSys Deca
Range of product
TeSys Deca
Product or component type
Contactor
Device short name
LC1D
contactor application
Motor control Resistive load
utilisation category
AC-3 AC-1 AC-3e
Poles description
3P
[Ue] rated operational voltage
Power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current
9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage
24 V AC 50/60 Hz
Motor power kW
4 kW at 380...400 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz 5.5 kW at 660...690 V AC 50/60 Hz 4 kW at 415...440 V AC 50/60 Hz 2.2 kW at 220...230 V AC 50/60 Hz 2.2 kW at 400 V AC (AC-4)
Motor power hp
0.5 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA 0.5 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL 1 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA 1 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors conforming to CSA 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors conforming to CSA 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors conforming to UL 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors conforming to CSA 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors conforming to UL 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors conforming to CSA 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors conforming to UL 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors conforming to UL
Compatibility code
LC1D
Pole contact composition
3 NO
Protective cover
With
[Ith] conventional free air thermal current
10 A (at 60 °C) for control circuit 25 A (at 60 °C) for power circuit
Irms rated making capacity
140 A AC for control circuit conforming to IEC 60947-5-1 250 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
250 kA at 440 V for power circuit conforming to IEC 60947
Associated fuse rating
10 A gG for control circuit conforming to IEC 60947-5-1 20 A at <= 690 V coordination type 2 for power circuit 25 A at <= 690 V coordination type 1 for power circuit
Average impedance
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Power dissipation per pole
0.2 W AC-3 1.56 W AC-1 0.2 W AC-3e
[Ui] rated insulation voltage
Control circuit: 600 V CSA certified Control circuit: 600 V UL certified Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Control circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category
III
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability
15000000 cycles
Control circuit type
AC at 50/60 Hz
Coil technology
Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
0.3...0.6 Uc (60 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (60 °C):operational AC 50 Hz 0.85...1.1 Uc (60 °C):operational AC 60 Hz
Inrush power in VA
70 VA cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA
7 VA 50/60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation
2…3 W at 50/60 Hz for control circuit
Operating time
4...19 ms opening 12...22 ms closing
Maximum operating rate
3600 cyc/h 60 °C
Connections - terminals
Control circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminal 2 1…2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminal 2 1…2.5 mm² - cable stiffness: flexible with cable end
Tightening torque
Control circuit: 1.7 N.m - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - with screwdriver Philips No 2 Power circuit: 1.7 N.m - with screwdriver flat Ø 6 mm Power circuit: 1.7 N.m - with screwdriver Philips No 2 Control circuit: 1.7 N.m - with screwdriver pozidriv No 2 Power circuit: 1.7 N.m - with screwdriver pozidriv No 2
Auxiliary contact composition
1 NO + 1 NC
Minimum switching voltage
17 V for control circuit
Minimum switching current
5 mA for control circuit
Insulation resistance
> 10 MOhm for control circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts
mounting support
Plate Rail
Standards
EN/IEC 60947-4-1 UL 508 CSA C22.2 No 14 EN/IEC 60947-5-1 IEC 60335-1
product certifications
UL DNV BV CSA LROS (Lloyds register of shipping) CCC GOST GL RINA UKCA
IP degree of protection
IP2X conforming to IEC 60529 IP2X conforming to VDE 0106
Climatic withstand
conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device
-5…60 °C -40…70 °C at Uc
Operating altitude
3000 m without derating
Fire resistance
850 °C conforming to IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Shocks contactor opened (10 Gn for 11 ms) Shocks contactor closed (15 Gn for 11 ms) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)
height
77 mm
Width
45 mm
Depth
86 mm
Net weight
3.2 kg
Quantity per set
Set of 10
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.700 cm
Package 1 Width
7.400 cm
Package 1 Length
8.800 cm
Package 1 Weight
334.000 g
Unit Type of Package 2
S02
Number of Units in Package 2
24
Package 2 Height
15.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
8.586 kg
Warranty
18 months
Datasheet