Trade Price
£57.63
Per
1
Unit
EA
Pack Quantity
1
These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This fourth pole adder can be added to a VLS3P063R2 DIN rail mount switch. This fourth pole adder for DIN rail mounted devices can be mounted on the right or left hand side. This simultaneous closing adder pole has one normally open contact The operational voltage of this fourth pole adder module is 600 Vac 50/60 Hz. This fourth pole adder module has a 60 A current rating. Fourth pole adder pole is 3.94 inches tall, 0.91 inches wide and 1.73 inches deep. It weighs 0.24 lbs. This fourth pole adder block is cULus Listed and meets IEC 60947-3 requirements.
Range
TeSys
Device short name
VLS1P
Product or component type
Additional pole
Performance level
High performance
Poles description
1P
Contacts type and composition
1 NO
contact operation
Simultaneous
Range compatibility
TeSys (TeSys VARIO LS) VLS3P
Network type
AC
Network frequency
50/60 Hz
Suitability for isolation
Yes
Mounting location
Right Left
mounting support
DIN rail
[Ue] rated operational voltage
690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
63 A (at 55 °C)
[Ithe] conventional enclosed thermal current
63 A
[Ie] rated operational current
60 A Ue: 600 V conforming to UL98 63 A AC-21A Ue: 400 V 63 A AC-21A Ue: 500 V 63 A AC-21A Ue: 690 V 63 A AC-22A Ue: 400 V 63 A AC-22A Ue: 500 V 63 A AC-22A Ue: 690 V 63 A AC-23A Ue: 400 V 63 A AC-23A Ue: 500 V 47 A AC-23A Ue: 690 V
Rated operational power in W
30 kW at 400 V (AC-23A) 45 kW at 500 V (AC-23A) 45 kW at 690 V (AC-23A)
Intermittent duty class
Class 120 - 60 %
Making capacity ( I Rms)
94.5 A at 690 V AC-21A 189 A at 690 V AC-22A 630 A at 690 V AC-23A
[Icm] rated short-circuit making capacity
3550 A at 690 V
[Icw] rated short-time withstand Rms current
2500 A at 690 V duration: 1 s
Rated conditional short-circuit current
50 kA at 400 V - associated fuse 63 A gG
Breaking capacity
94.5 A at 690 V (AC-21A) 189 A at 690 V (AC-22A) 504 A at 690 V (AC-23A)
Mechanical durability
30000 cycles
Electrical durability
30000 cycles AC-21
Connections - terminals
Power circuit: screw clamp terminals50 mm² - solid Power circuit: screw clamp terminals70 mm² - flexible - without cable end
Tightening torque
Power circuit: 5…6 N.m - on screw clamp terminals
height
100 mm
Width
23 mm
Depth
48.6 mm
Net weight
0.11 kg
Colour
Grey
standards
UL98 CSA C22.2 No 4 IEC 60947-3
product certifications
cULus GL
IP degree of protection
IP20 conforming to IEC 60529
Mechanical robustness
Vibrations 2...100 Hz Fc (0.7 g) conforming to IEC 60068-2-6 Shocks 11 ms Ea (15 gn) conforming to IEC 60068-2-27
Ambient air temperature for operation
-25…55 °C
Fire resistance
960 °C conforming to IEC 60695-2-11
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
6.400 cm
Package 1 Width
11.300 cm
Package 1 Length
7.300 cm
Package 1 Weight
130.000 g
Unit Type of Package 2
S03
Number of Units in Package 2
36
Package 2 Height
30.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
6.680 kg
Warranty
18 months
Datasheet