Trade Price
POA
Per
1
Unit
EA
Pack Quantity
1
Range
TeSys TeSys Deca
Range of product
TeSys Deca
Product or component type
Contactor
Device short name
LC1D
contactor application
Resistive load
utilisation category
AC-1 AC-3 AC-3e AC-4
Poles description
4P
[Ue] rated operational voltage
Power circuit: <= 1000 V AC 25...400 Hz
[Ie] rated operational current
125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Pole contact composition
4 NO
Contact compatibility
M4
Protective cover
With
[Ui] rated insulation voltage
Power circuit: 1000 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947
Overvoltage category
III
[Ith] conventional free air thermal current
125 A (at 60 °C) for power circuit
Irms rated making capacity
1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating
200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit
Time constant
75 ms
Control circuit type
DC wide range
Coil technology
Without built-in suppressor module
Control circuit voltage limits
0.1...0.3 Uc (-40…70 °C):drop-out DC 0.7...1.25 Uc (-40…50 °C):operational DC 1...1.25 Uc (50…70 °C):operational DC
Average impedance
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole
12.5 W AC-1
Operating time
95...130 ms closing 20...35 ms opening
Maximum operating rate
3600 cyc/h 60 °C
Inrush power in W
22 W (at 20 °C)
Hold-in power consumption in W
22 W at 20 °C
Connections - terminals
Control circuit: lugs-ring terminals - external diameter: 8 mm Power circuit: lugs-ring terminals - external diameter: 17 mm Power circuit: bars 1 - busbar cross section: 3 x 16 mm
Tightening torque
Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5 Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5 Power circuit: 5 N.m - on lugs-ring terminals hexagonal screw head 10 mm M6 Power circuit: 5 N.m - on lugs-ring terminals - with screwdriver flat Ø 8 mm M6 Power circuit: 5 N.m - on bars - with screwdriver flat Ø 8 mm M6 Power circuit: 5 N.m - on bars hexagonal screw head 10 mm M6
mounting support
Plate Rail
Electrical durability
0.8 Mcycles 125 A AC-1 at Ue <= 440 V
Mechanical durability
10 Mcycles
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Operating altitude
0...3000 m
Compatibility code
LC1D
Standards
EN/IEC 60947-4-1 EN/IEC 60947-5-1 EN 45545: R22 HL3 EN 45545: R26 HL3 DIN 5510-2
product certifications
IEC CCC UKCA
Climatic withstand
conforming to IACS E10
Ambient air temperature for storage
-60…80 °C
Fire resistance
850 °C conforming to IEC 60695-2-1
height
127 mm
Width
96 mm
Depth
181 mm
Net weight
2.685 kg
Mechanical robustness
Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (8 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
11.0 cm
Package 1 Width
16.0 cm
Package 1 Length
22.0 cm
Package 1 Weight
2.632 kg
Unit Type of Package 2
S02
Number of Units in Package 2
2
Package 2 Height
15 cm
Package 2 Width
30 cm
Package 2 Length
40 cm
Package 2 Weight
5.494 kg
Warranty
18 months
Datasheet