LC1D806SWS207

LC1D 3P AC3 440V 80A COIL 72V

Trade Price

POA

Per

1

Unit

EA

Pack Quantity

1

LC1D806SWS207

Technical Specifications

Range

TeSys TeSys Deca

Range of product

TeSys Deca

Product or component type

Contactor

Device short name

LC1D

contactor application

Motor control Resistive load

utilisation category

AC-3 AC-1 AC-3e

Poles description

3P

[Ue] rated operational voltage

Power circuit: <= 1000 V AC 25...400 Hz

[Ie] rated operational current

125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

Motor power kW

22 kW at 220/230 V AC 50 Hz (AC-3) 37 kW at 380/400 V AC 50 Hz (AC-3) 45 kW at 415 V AC 50 Hz (AC-3) 45 kW at 440 V AC 50 Hz (AC-3) 55 kW at 500 V AC 50 Hz (AC-3) 45 kW at 660/690 V AC 50 Hz (AC-3) 45 kW at 1000 V AC 50 Hz (AC-3)

Pole contact composition

3 NO

Contact compatibility

M9

Protective cover

With

Auxiliary contacts type

type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1

Auxiliary contact composition

1 NO + 1 NC

[Ui] rated insulation voltage

Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage

8 kV conforming to IEC 60947

Overvoltage category

III

[Ith] conventional free air thermal current

125 A (at 60 °C) for power circuit 10 A (at 60 °C) for signalling circuit

Irms rated making capacity

1100 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1

Rated breaking capacity

1100 A at 440 V for power circuit conforming to IEC 60947

Associated fuse rating

200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit conforming to IEC 60947-5-1

Time constant

75 ms

Control circuit type

DC wide range

Coil technology

Without built-in suppressor module

Control circuit voltage limits

0.1...0.3 Uc (-40…70 °C):drop-out DC 0.7...1.25 Uc (-40…50 °C):operational DC 1...1.25 Uc (50…70 °C):operational DC

Average impedance

0.8 mOhm - Ith 125 A 50 Hz for power circuit

Power dissipation per pole

12.5 W AC-1 5.1 W AC-3 6.5 W AC-3e

Minimum switching current

5 mA for signalling circuit

Minimum switching voltage

17 V for signalling circuit

Non-overlap time

1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact

Operating time

95...130 ms closing 20...35 ms opening

Maximum operating rate

3600 cyc/h 60 °C

Inrush power in W

22 W (at 20 °C)

Hold-in power consumption in W

22 W at 20 °C

Insulation resistance

> 10 MOhm for signalling circuit

Connections - terminals

Control circuit: lugs-ring terminals - external diameter: 8 mm Power circuit: lugs-ring terminals - external diameter: 17 mm Power circuit: bars 1 - busbar cross section: 3 x 16 mm

Tightening torque

Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5 Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5 Power circuit: 5 N.m - on lugs-ring terminals hexagonal screw head 10 mm M6 Power circuit: 5 N.m - on lugs-ring terminals - with screwdriver flat Ø 8 mm M6 Power circuit: 5 N.m - on bars - with screwdriver flat Ø 8 mm M6 Power circuit: 5 N.m - on bars hexagonal screw head 10 mm M6 Power circuit: 2.5 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M4 Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5

mounting support

Plate Rail

Electrical durability

1.5 Mcycles 80 A AC-3 at Ue <= 440 V 0.8 Mcycles 125 A AC-1 at Ue <= 440 V 1 Mcycles 66 A AC-3e at Ue <= 440 V

Mechanical durability

10 Mcycles

Safety reliability level

B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Operating altitude

0...3000 m

Compatibility code

LC1D

Standards

EN/IEC 60947-4-1 EN/IEC 60947-5-1 EN 45545: R22 HL3 EN 45545: R26 HL3 DIN 5510-2

product certifications

IEC CCC UKCA

Climatic withstand

conforming to IACS E10

Ambient air temperature for storage

-60…80 °C

Fire resistance

850 °C conforming to IEC 60695-2-1

height

127 mm

Width

85 mm

Depth

186 mm

Net weight

2.59 kg

Mechanical robustness

Vibrations contactor open (2 Gn, 5...300 Hz) Shocks contactor closed (15 Gn for 11 ms) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (8 Gn for 11 ms)

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

10.7 cm

Package 1 Width

16.2 cm

Package 1 Length

21.7 cm

Package 1 Weight

2.543 kg

Unit Type of Package 2

S02

Number of Units in Package 2

2

Package 2 Height

15.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

5.357 kg

Warranty

18 months

Document Links

Datasheet