GV4PEM07N

GV4PE MultiTh/Mag 7A 50kA Elink

Trade Price

£641.74

Per

1

Unit

EA

Pack Quantity

1

GV4PEM07N

Information

TeSys GV motor circuit breaker, 3 poles (3P), 7A/690V, for protection of 3-phase motors 1.5-3kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 2.9-7A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

Technical Specifications

Range of product

TeSys GV4

Range

TeSys Deca TeSys Deca

Device short name

GV4PEM

Product name

TeSys GV4 TeSys Deca

Product or component type

Motor circuit breaker

Device application

Motor protection

Trip unit technology

Electronic Thermal-magnetic

Poles description

3P

Utilisation category

Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1

Operating position

Any position

Motor power kW

1.5 kW at 400...415 V AC 50/60 Hz 2.2 kW at 400...415 V AC 50/60 Hz 2.5 kW at 400...415 V AC 50/60 Hz 3 kW at 400...415 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz 2.5 kW at 500 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz 4 kW at 500 V AC 50/60 Hz 3 kW at 660...690 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 5.5 kW at 660...690 V AC 50/60 Hz 7.5 kW at 660...690 V AC 50/60 Hz

Breaking capacity

100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947 65 kA at 240 V AC 50/60 Hz conforming to UL 60947 35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947

Control type

Toggle

[In] rated current

7 A

Magnetic tripping current

119 A

[Ue] rated operational voltage

690 V AC 50/60 Hz conforming to IEC 60947-2

[Ui] rated insulation voltage

800 V AC 50/60 Hz conforming to IEC 60947-2

[Ith] conventional free air thermal current

115 A conforming to IEC 60947-4-1

[Uimp] rated impulse withstand voltage

8 kV conforming to IEC 60947-2

Power dissipation per pole

4.6 W

Mechanical durability

40000 cycles

Electrical durability

40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In

Maximum operating rate

25 cyc/h

Rated duty

Continuous conforming to IEC 60947-4-1

Connections - terminals

EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible

Tightening torque

9 N.m for cable 16…95 mm² 5 N.m for cable 1.5…10 mm²

Mechanical robustness

Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27

Phase failure sensitivity

Yes conforming to IEC 60947-4-1

height

155 mm

Width

81 mm

Depth

116 mm

Net weight

1.45 kg

Colour

Grey (RAL 7016)

Suitability for isolation

Yes conforming to IEC 60947-1

standards

CSA C22.2 No 60947-4-1 UL 60947-4-1 EN/IEC 60947-4-1 EN/IEC 60947-2

product certifications

IEC UL CSA CCC EAC ATEX EU-RO MR

Climatic withstand

conforming to IACS E10

IK degree of protection

IK07 conforming to IEC 62262

Pollution degree

3

IP degree of protection

IP40 conforming to IEC 60529

Ambient air temperature for storage

-50…85 °C

Fire resistance

960 °C conforming to IEC 60695-2-11

Operating altitude

5000 m

Ambient air temperature for operation

-25…70 °C

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

17.0 cm

Package 1 Width

11.0 cm

Package 1 Length

22.0 cm

Package 1 Weight

1.67 kg

Unit Type of Package 2

S03

Number of Units in Package 2

5

Package 2 Height

30 cm

Package 2 Width

30 cm

Package 2 Length

40 cm

Package 2 Weight

9 kg

Warranty

18 months

Document Links

Datasheet