XESD1181

CONTACT BLOCK

Trade Price

POA

Per

1

Unit

EA

Pack Quantity

1

XESD1181

Information

This contact block allows fast and easy replacement and configuration of your push buttons and selector switches It protects operators from unexpected contact with live circuits It is easily installed and replaced on XACM and XACB pendant control stations and connects to control circuits with simple screw-clamp connections

Technical Specifications

Range of product

Harmony XAC

Product or component type

Contact block

Component name

XESD

Electrical circuit type

Control circuit

Contact block application

Single speed

Contact block type

Double

Type of operator

2 spring return

Product compatibility

XACB XACM

Mechanical interlocking

With mechanical interlocking

Mounting of block

Front mounting

contact operation

Snap action

Connections - terminals

Screw clamp terminals, 1 x 2.5 mm² with or without cable end Screw clamp terminals, 2 x 1.5 mm² with or without cable end

Mechanical durability

1000000 cycles

Contact code designation

A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A

[Ithe] conventional enclosed thermal current

10 A

[Ui] rated insulation voltage

500 V (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947-1

Maximum resistance across terminals

25 MOhm

Operating force

15 N 25 N

Short-circuit protection

10 A fuse protection by cartridge fuse type gG

Rated operational power in W

140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 95 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C

Rated operational power in VA

100 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load) 450 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load) 50 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load) 750 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)

Terminals description ISO n°1

B (13-14-11-12)OF

Terminals description ISO n°2

B (23-24-21-22)OF

Terminal identifier

(13-14)NO (11-12)NC

standards

CSA C22.2 No 14 EN 60947-5-1 IEC 60947-5-1

Ambient air temperature for operation

-25…70 °C

Ambient air temperature for storage

-40…70 °C

Vibration resistance

15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6

Shock resistance

100 gn conforming to IEC 60068-2-27

Electrical shock protection class

Class II conforming to IEC 61140

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

7.1 cm

Package 1 Width

7.2 cm

Package 1 Length

8.9 cm

Package 1 Weight

156.0 g

Unit Type of Package 2

S02

Number of Units in Package 2

10

Package 2 Height

15.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

1.99 kg

Warranty

18 months

Document Links

Datasheet