XENB1191

CONTACT BLOCK

Trade Price

POA

Per

1

Unit

EA

Pack Quantity

1

XENB1191

Information

This Harmony XENB1191 is a pendant station contact 240V AC 3A. It is part of the range Harmony XAC pendant control stations for diameter 22mm plastic signaling units. It is designed for 2-speed applications.

Technical Specifications

Range of product

Harmony XAC

Product or component type

Contact block

Component name

XENB

Electrical circuit type

Control circuit

Contact block application

2-speed

Contact block type

Single

Type of operator

Spring return

Product compatibility

XACB XACM

Mechanical interlocking

Without mechanical interlock

Contacts type and composition

1 C/O + 1 NO

Mounting of block

Front mounting

contact operation

Slow-break Staggered

Connections - terminals

Screw clamp terminals, 1 x 2.5 mm² with or without cable end Screw clamp terminals, 2 x 1.5 mm² with or without cable end

Mechanical durability

1000000 cycles

Contact code designation

A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A

[Ithe] conventional enclosed thermal current

10 A

[Ui] rated insulation voltage

400 V (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947-1

Maximum resistance across terminals

25 MOhm

Short-circuit protection

10 A fuse protection by cartridge fuse type gG

Rated operational power in W

31 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 35 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C

Rated operational power in VA

140 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load) 210 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load) 640 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load) 680 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)

Terminals description ISO n°1

(13-14-31-32)OF (23-24)NO_CL

Terminal identifier

(11-12)NC (13-14)NO

Net weight

0.05 kg

standards

IEC 60947-5-1 CSA C22.2 No 14 EN 60947-5-1

Ambient air temperature for operation

-25…70 °C

Ambient air temperature for storage

-40…70 °C

Vibration resistance

15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6

Shock resistance

100 gn conforming to IEC 60068-2-27

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

3.000 cm

Package 1 Width

5.000 cm

Package 1 Length

6.000 cm

Package 1 Weight

54.300 g

Unit Type of Package 2

S02

Number of Units in Package 2

50

Package 2 Height

15.000 cm

Package 2 Width

30.000 cm

Package 2 Length

40.000 cm

Package 2 Weight

2.938 kg

Unit Type of Package 3

P06

Number of Units in Package 3

800

Package 3 Height

75.000 cm

Package 3 Width

80.000 cm

Package 3 Length

60.000 cm

Package 3 Weight

55.016 kg

Warranty

18 months

Document Links