Trade Price
POA
Per
1
Unit
EA
Pack Quantity
1
This Harmony XENB1191 is a pendant station contact 240V AC 3A. It is part of the range Harmony XAC pendant control stations for diameter 22mm plastic signaling units. It is designed for 2-speed applications.
Range of product
Harmony XAC
Product or component type
Contact block
Component name
XENB
Electrical circuit type
Control circuit
Contact block application
2-speed
Contact block type
Single
Type of operator
Spring return
Product compatibility
XACB XACM
Mechanical interlocking
Without mechanical interlock
Contacts type and composition
1 C/O + 1 NO
Mounting of block
Front mounting
contact operation
Slow-break Staggered
Connections - terminals
Screw clamp terminals, 1 x 2.5 mm² with or without cable end Screw clamp terminals, 2 x 1.5 mm² with or without cable end
Mechanical durability
1000000 cycles
Contact code designation
A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
400 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
Maximum resistance across terminals
25 MOhm
Short-circuit protection
10 A fuse protection by cartridge fuse type gG
Rated operational power in W
31 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 35 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Rated operational power in VA
140 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load) 210 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load) 640 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load) 680 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)
Terminals description ISO n°1
(13-14-31-32)OF (23-24)NO_CL
Terminal identifier
(11-12)NC (13-14)NO
Net weight
0.05 kg
standards
IEC 60947-5-1 CSA C22.2 No 14 EN 60947-5-1
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Vibration resistance
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance
100 gn conforming to IEC 60068-2-27
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3.000 cm
Package 1 Width
5.000 cm
Package 1 Length
6.000 cm
Package 1 Weight
54.300 g
Unit Type of Package 2
S02
Number of Units in Package 2
50
Package 2 Height
15.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
2.938 kg
Unit Type of Package 3
P06
Number of Units in Package 3
800
Package 3 Height
75.000 cm
Package 3 Width
80.000 cm
Package 3 Length
60.000 cm
Package 3 Weight
55.016 kg
Warranty
18 months