This Harmony XESB2011 is a pendant station contact 600V AC 10A. It is part of the range Harmony XAC pendant control stations for diameter 22mm plastic signaling units.
Range of product
Harmony XAC
Product or component type
Contact block
Component name
XESB
Electrical circuit type
Control circuit
Contact block application
Single speed
Contact block type
Single
Type of operator
Spring return
Product compatibility
XACM XACB XAB91...
Mechanical interlocking
Without mechanical interlock
Mounting of block
Front mounting
contact operation
Snap action
Connections - terminals
Screw clamp terminals, 1 x 2.5 mm² with or without cable end Screw clamp terminals, 2 x 1.5 mm² with or without cable end
Mechanical durability
1000000 cycles
Contact code designation
A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
500 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
Maximum resistance across terminals
25 MOhm
Operating force
25 N 15 N
Short-circuit protection
10 A fuse protection by cartridge fuse type gG
Rated operational power in W
140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 95 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Rated operational power in VA
100 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load) 450 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load) 50 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load) 750 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)
Terminals description ISO n°1
(3-4-1-2)OF
Terminal identifier
(13-14)NO (11-12)NC
standards
IEC 60947-5-1 CSA C22.2 No 14 IEC 60947-5-1
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Vibration resistance
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance
100 gn conforming to IEC 60068-2-27
Electrical shock protection class
Class II conforming to IEC 61140
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.3 cm
Package 1 Width
6.4 cm
Package 1 Length
8.6 cm
Package 1 Weight
30.0 g
Unit Type of Package 2
S02
Number of Units in Package 2
100
Package 2 Height
15.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
3.206 kg
Warranty
18 months
Datasheet