Trade Price
POA
Per
1
Unit
Pack Quantity
This wireless control station emergency stop function is ideal for situations where quick actions are required for a process or machine to function correctly or where operator movements require maximum ergonomy It has motion function and limiter protection function. Its schematic is clearly distinguishable thanks to clear colors It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant, making it ideal for operation in harsh environments The product is composed of a remote ZART8D , a base ZARB18W , a charger , a shoulder belt , a CABLE USB/RJ45 and a config software High performance International standards & certifications (IP69K, IK03, Type 4X)
Range of product
Harmony eXLhoist
Product or component type
Control station
Device short name
XARS
Control station type
Wireless
Product specific application
Hoisting applications Material handling
Number of channels
50
Control station application
Stop function: SIL 2 maximum (can reach PL d/category 3) conforming to IEC 62061 Stop function: SIL 2 maximum (can reach PL d/category 3) conforming to ISO 13849-1 Emergency stop function: SIL 3 maximum (can reach PL e/category 4) conforming to IEC 62061 Emergency stop function: SIL 3 maximum (can reach PL e/category 4) conforming to ISO 13849-1 Motion function: SIL 1 maximum (can reach PL c/category 1) conforming to IEC 62061 Motion function: SIL 1 maximum (can reach PL c/category 1) conforming to ISO 13849-1 Limiter protection function: SIL 1 maximum (can reach PL c/category 1) conforming to IEC 62061 Limiter protection function: SIL 1 maximum (can reach PL c/category 1) conforming to ISO 13849-1
Kit composition
Remote control Base station Shoulder belt Cable Configuration software
Operating distance
100 m in free air
Cable entry
Cable gland
Communication network type
Wireless: bluetooth low energy
Transmission frequency
2.4 GHz
Radio agreement
SRRC RSS ARIB ANATEL FCC ICASA
Relative humidity
0…95 % at -20…45 °C storage
Electromagnetic compatibility
Resistance to electrostatic discharge - test level: 4 kV class B (on contact) conforming to IEC 61000-4-2 Resistance to electrostatic discharge - test level: 8 kV class B (in air) conforming to IEC 61000-4-2 Resistance to radiated electromagnetic fields - test level: 10 V/m class B conforming to IEC 61000-4-3
Standards
IEC 60204-1 safety ISO 13849-1 safety IEC 62061 safety IEC 61508 safety ISO 13850 safety IEC 60204-32 hoisting applications ETSI EN 301 489-1 radio ETSI EN 301 489-3 radio ETSI EN 301 489-17 radio ETSI EN 300 440-2 radio ETSI EN 300 328 radio FCC part 15 radio RSS GEN issue 3 radio RSS 210 issue 8 radio ARIB STD-T81 radio
Product certifications
CE UL CSA C-Tick JIS KC EAC
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
20.5 cm
Package 1 Width
29.0 cm
Package 1 Length
30.8 cm
Package 1 Weight
3.148 kg
Unit Type of Package 2
S04
Number of Units in Package 2
2
Package 2 Height
30.0 cm
Package 2 Width
40.0 cm
Package 2 Length
60.0 cm
Package 2 Weight
6.884 kg
Warranty
18 months