XALD132

ConStn RedSWNC mrk Arret-Marche

Trade Price

POA

Per

1

Unit

EA

Pack Quantity

1

XALD132

Information

This Harmony XALD yellow control station for start/stop function is ideal for your complete control station. It operates with 2 positions stay put mechanism and uses screw-clamp terminals. This control station with flush push buttons is ideal to control start / stop operation in your machines. Its schematic is clearly distinguishable thanks to clear colors and markings. It is impact resistant, dust resistant, water resistant, corrosion resistant, and vibration resistant thanks to its IP69 / IP67 / IP66 / IP69K, making it ideal for operation in harsh environments. Its wide range of operating temperatures from -40°C to 70°C allows versatility in usage of product. Vibration resistant screw clamp connection terminals ensure high vibration resistance making product suitable installation on high impact machine.

Technical Specifications

Range of product

Harmony XALD

Product or component type

Complete control station

Device short name

XALD

Product destination

For XB5 Ø 22 mm control and signalling units

Control station application

Start-Stop function

Colour of base of enclosure

Light grey (RAL 7035)

Colour of cover

Dark grey (RAL 7016)

Material

Polycarbonate

Operator profile

1 selector switch with handle

Operators description

Standard handle ''ARRET-MARCHE'' 1 NO

Control station composition

1 selector switch with standard handle 1 NO ARRET-MARCHE marking

marking location

Marking on legend holder

contact operation

Slow-break

Cable entry

2 knock-outs for cable entry, clamping capacity: 14 mm 2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm

Net weight

0.163 kg

Resistance to high pressure washer

7000000 Pa at 55 °C, distance : 0.1 m

Operator position information

2 positions

Positive opening

Without

Operating travel

4.3 mm (total travel)

Torque value

0.14 N.m NO changing electrical state

Mechanical durability

1000000 cycles

Connections - terminals

Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1

Tightening torque

0.8…1.2 N.m conforming to IEC 60947-1

Shape of screw head

Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver

Contacts material

Silver alloy (Ag/Ni)

Short-circuit protection

10 A cartridge fuse type gG conforming to IEC 60947-5-1

[Ith] conventional free air thermal current

10 A conforming to IEC 60947-5-1

[Ui] rated insulation voltage

600 V (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947-1

[Ie] rated operational current

6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1

Electrical durability

1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

Electrical reliability

Λ < 10exp(-6) at 5 V, 1 mA conforming to IEC 60947-5-4 Λ < 10exp(-8) at 17 V, 5 mA conforming to IEC 60947-5-4

Protective treatment

TH

Ambient air temperature for storage

-40…70 °C

Ambient air temperature for operation

-40…70 °C

Overvoltage category

Class II conforming to IEC 60536

IP degree of protection

IP66 conforming to IEC 60529 IP67 IP69 IP69K

NEMA degree of protection

NEMA 13 NEMA 4X

IK degree of protection

IK05 conforming to IEC 62262

standards

IEC 60947-1 IEC 60947-5-5 IEC 60947-5-4 JIS C8201-5-1 CSA C22.2 No 14 IEC 60947-5-1 UL 508 JIS C8201-1

Vibration resistance

5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6

Shock resistance

30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

7.2 cm

Package 1 Width

10.0 cm

Package 1 Length

7.2 cm

Package 1 Weight

146.0 g

Unit Type of Package 2

S03

Number of Units in Package 2

40

Package 2 Height

30 cm

Package 2 Width

30 cm

Package 2 Length

40 cm

Package 2 Weight

6.284 kg

Warranty

18 months

Document Links

Datasheet