Technical Specifications

Range of product

Harmony XAC

Product or component type

Pendant control station

Device short name

XACA

Control station type

Double insulated

Enclosure material

Polypropylene

Electrical circuit type

Control circuit

Enclosure type

Complete ready for use

Control station application

Control of single speed hoist motor

Control station composition

4 push-buttons + 1 emergency stop

Control button type

First push-button 1 NC + 1 NO raise, slow Second push-button 1 NC + 1 NO lower, slow Emergency stop push-button Ø 40 mm 3 NC trigger action Fourth push-button 1 NC + 1 NO left, slow Third push-button 1 NC + 1 NO right, slow

Product compatibility

ZB2BE102 + ZB2BE101 for each direction XENT1192 for emergency stop

Mechanical interlocking

With mechanical interlocking between pairs

Control station colour

Yellow

Connections - terminals

Screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end

standards

EN/IEC 60204-32 EN/IEC 60947-5-5 CSA C22.2 No 14 EN/IEC 60947-5-1 EN/ISO 13850: 2006 UL 508

product certifications

CCC GOST

Protective treatment

TH

Ambient air temperature for operation

-25…70 °C

Ambient air temperature for storage

-40…70 °C

Vibration resistance

15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6

Shock resistance

100 gn conforming to IEC 60068-2-27

Overvoltage category

Class II conforming to IEC 61140

IP degree of protection

IP65 conforming to IEC 60529

IK degree of protection

IK08 conforming to EN 50102

Mechanical durability

1000000 cycles

Cable entry

Rubber sleeve with stepped entry 8…26 mm

Contact code designation

A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A

[Ithe] conventional enclosed thermal current

10 A

[Ui] rated insulation voltage

Emergency stop contact: 400 V (pollution degree 3) conforming to IEC 60947-1 600 V (pollution degree 3)

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947-1

contact operation

Slow-break

Maximum resistance across terminals

25 MOhm

Operating force

13 N push-button 14 N emergency stop

Short-circuit protection

10 A fuse protection by cartridge fuse type gG

Rated operational power in W

40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C

Terminals description ISO n°1

(11-12)NC (13-14)NO

Terminals description ISO n°2

(21-22)NC (31-32)NC (11-12)NC

Terminal identifier

(13-14)NO (11-12)NC

Net weight

0.85 kg

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

8.5 cm

Package 1 Width

9.0 cm

Package 1 Length

35.0 cm

Package 1 Weight

600.0 g

Warranty

18 months