Trade Price
£792.33
Per
1
Unit
EA
Pack Quantity
1
This PowerTag Energy M250 3P is a wireless communication energy sensor. With its Monoconnect design, it is dedicated to Compact NSX 100/160/250, Compact NS 100/160/250 and TeSys GV5/GV7. It has to be associated with a concentror or a gateway to provide circuit monitoring and diagnosis down to load level. It is designed specifically for Energy Management, Load Monitoring and Power Availability applications. It incorporates accurate real-time measurements of active, and reactive energy, active, reactive and apparent power, current, voltage and power factor. In case of power outage, it sends a voltage loss alarm and the current-per-phase value before being de-energized. PowerTag Energy M250 complies with IEC 61557-12 standard. It is a PMD-II/DD/K70/1. The Performance category is Class 1. The Imax maximum current is 250A. The Ib Base current is 40A. The Saturation current is 500A and the Ist Starting current is 160mA. The Un Rated voltages are Phase-to-neutral 230VAC +/- 20% and Phase-to-phase 400VAC +/- 20%. The maximum consumption is below or equal to 3.7VA. It can be mounted directly on the bottom side of the circuit breaker or Vigi add-on terminals, or top or bottom side of the plug-in base if any. The product color is grey (RAL7016). The weight is 250g. The degree of protection is IP20 and IK07. The operating temperature is between -25°C to +70°C. The storage temperature is between -50°C to +85°C.
Range of product
PowerLogic
Product name
PowerTag M250
Product or component type
Energy sensor
Poles
3P
Maximum current [Imax]
250 A
[Ib] basic current
40 A
starting current
160 mA
Saturation current
500 A
Product specific application
Energy management Overload alarm Power factor Load monitoring Circuit monitoring
Concentrator compatibility
Acti9 Smartlink SI B Acti9 Smartlink SI D Acti9 PowerTag Link C Acti9 PowerTag Link Acti9 PowerTag Link HD Harmony Hub Wiser IP module EcoStruxure Panel Server Universal EcoStruxure Panel Server Advanced PrismaSet Active
Range compatibility
Compact NSX Compact NSX100...250 Compact NS Compact NS100...250 TeSys TeSys GV5 TeSys TeSys GV7 EasyPact EasyPact CVS100 EasyPact EasyPact CVS160 EasyPact EasyPact CVS250
Type of measurement
Active and reactive energy Active and reactive power Apparent power Current Voltage Power factor
Accuracy class
Class 1 active energy conforming to IEC 61557-12 Class 2 reactive energy conforming to IEC 61557-12 Class 1 active power conforming to IEC 61557-12 Class 2 reactive power conforming to IEC 61557-12 Class 2 apparent power conforming to IEC 61557-12 Class 1 current conforming to IEC 61557-12 Class 0.5 voltage conforming to IEC 61557-12 Class 1 power factor conforming to IEC 61557-12
Metering type
Power factor 0...1: class 1 at 25 °C conforming to IEC 61557-12 Apparent power S, S1, S2, S3 88 VA...416 kVA: class 2 at 25 °C conforming to IEC 61557-12 Active power P, P1, P2, P3 88 W...416 kW: class 1 at 25 °C conforming to IEC 61557-12 Reactive power Q, Q1, Q2, Q3 88 VAR...416 kVAR: class 2 at 25 °C conforming to IEC 61557-12 Active energy Ep IN/OUT/tot 0...281 x 10exp(9) kWh: class 1 at 25 °C conforming to IEC 61557-12 Reactive energy Ep IN/OUT/tot 0...281 x 10exp(9) kVARh: class 2 at 25 °C conforming to IEC 61557-12 Voltage U12, U23, U31 320...480 V: class 0.5 at 25 °C conforming to IEC 61557-12 Voltage V1N, V2N, V3N 184...276 V: class 0.5 at 25 °C conforming to IEC 61557-12 Current I1, I2, I3, Iavg 8...250 A: class 1 at 25 °C conforming to IEC 61557-12 Frequency 45...65 Hz
Mounting location
Bottom
mounting support
On circuit breaker
Connection pitch
35 mm
Product destination
Switchboard
Event management
Voltage loss with measured current at voltage loss
Transmission support medium
Radio frequency 2.4…2.4835 GHz conforming to IEEE 802.15.4 (11…26) transmission time < 5 ms
maximum emission power
10 mW
[Imp] maximum permanent current
1.2 x In
Mounting mode
Bolt-on
Tightening torque
10 N.m
supply voltage
230 V AC, +/- 20 %, between phase and neutral 400 V AC, +/- 20 %, between phases
Network frequency
50 Hz 60 Hz
Maximum power consumption
3.7 VA
Standards
IEC 61557-12 IEC 61010-1 ETSI EN 301 487-1 IEC 61010-2-030 IEC 61326-1 ETSI EN 300 328
Height
57 mm
Width
105 mm
Depth
86 mm
Net weight
250 g
Colour
Dark grey (RAL 7016)
Quality labels
CE
Directives
2014/53/EU - radio equipment directive
Operating altitude
0...2000 m
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-50…85 °C
Overvoltage category
IV conforming to IEC 61010-1
Measurement category
Category III conforming to IEC 61010-2-030
IP degree of protection
IP20
IK degree of protection
IK07 conforming to IEC 60068-2-75 test Ehb
Pollution degree
3
Relative humidity
0…95 % at 55 °C conforming to IEC 60721-3-3
Vibration resistance
3M4 conforming to IEC 60721-3-3
Electromagnetic compatibility
Industrial electromagnetic environment conforming to IEC 61326-1 Radiated EMC conforming to ETSI EN 301 489-17 Electromagnetic emission conforming to IEC 62311
environmental characteristics
Indoor use
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
13.000 cm
Package 1 Width
11.100 cm
Package 1 Length
13.400 cm
Package 1 Weight
462.0 g
Unit Type of Package 2
S02
Number of Units in Package 2
4
Package 2 Height
15.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
2.311 kg
Unit Type of Package 3
P06
Number of Units in Package 3
64
Package 3 Height
71.500 cm
Package 3 Width
60.000 cm
Package 3 Length
80.000 cm
Package 3 Weight
43.000 kg
Warranty
18 months
Datasheet