A9XMSB11

SMART MODBUS RS485 COMMUNICATING I/O MOD

Trade Price

POA

Per

1

Unit

Pack Quantity

A9XMSB11

Information

This Acti 9 SmartLink Modbus Slave is a smart communication module with 11 channels. It communicates with the auxiliaries iACT24 for iCT contactors, iATL24 for iTL impulse relays, iOF+SD24 for iC60, iID, ARA, RCA & iSW-NA. It needs to be associated to a Master SmartLink SI B thanks to the Modbus RS485 connector. It is used to transfer data from Acti 9 devices to a PLC or network monitoring system thanks to the Ethernet connector. It communicates also with OF+SD24 for C60, C120, DPN, ID & C60H-DC, Ti24 for RCA iC60 & Reflex iC60. It is supplied with 1 power supply connector 24VDC, 2 bolts for mounting on Linergy FM80. The link is Modbus, RTU, RS485 serial connection. The transfer rate is self-adaptable from 9600 to 19200 baud. The Modbus addresing range is 1 to 99. It is a 4-pin connector type of bus. It is a plug-in connection. The maximum length of the bus is 1000m. The maximum cable length is 500m. The voltage power supply is 24VDC +/- 10%. The Maximum input current is 1,5A. The Maximum inrush current is 3A. The degree of protection is IP20. The pollution degree is 3. It complies with RoHS directive. The duration of saving memory is 10 years. The dimensions are (W) 359mm x (H) 23mm x (D) 42mm. The weigth is 195g. The operating temperature is -25°C to + 60°C and only +50°C if vertical mouting. The storage temperature is -40°C to + 80°C. This product complies with IEC/EN 61131-2 standard.

Technical Specifications

range of product

EcoStruxure

Product name

EcoStruxure I/O Smart Link

Product or component type

Smart communication module

Device short name

Smartlink Modbus

Application type

Load control Breaker status monitoring Basic energy metering E

Number max of connected devices

Up to 11 wired devices

group of channels

1 group of 11 digital channels

Maximum supply current

1.5 A

[Us] rated supply voltage

24 V DC +/- 20 %

Connectivity to devices

Digital input and output Pulse output meter

Communication service

Modbus server for RS485

Web server

BMS controller compatible

Web services

Web page

application specific I/O

Pulse totalising counter Pulse converter

Protection type

Against reverse polarity for auxiliary supply Against reverse polarity for input Overvoltage at 33 V DC for digital output

Immunity to microbreaks

10 ms

Reset

Factory reset on front face By booted push-button By address encoder By plug in, plug out the power supply

input/output type

2 inputs + 1 output per digital channel

Input type

Current sink for digital input, 24 V DC +/- 20 % at 2.5 mA

Maximum permanent current

5 mA for digital input

Electronic filtering time

2 ms for digital input from state 0 to state 1

Output type

Logic current source: 24 V - DC - 100 mA

Maximum voltage drop

<1 V at state 1 digital output

Inrush current

0.5 A for digital output 7 A for power supply

Local signalling

Communication: 1 LED (yellow) Status: 1 LED (green, orange and red)

Type of setting

Modbus address 01...99 for address encoders Reset for address encoders Reset for plug in, plug out the auxiliary supply

Mounting position

Horizontal and vertical on DIN rail

Colour

White (RAL 9003)

Location of connection

Front

Connections - terminals

Spring-loaded terminal Ti24 qty: 11 for digital input/output, ordered separately Plug-in connector qty: 1 for supply circuit Plug-in connector qty: 1 for communication bus

Clamping connection capacity

2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible with cable end for communication bus 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible without cable end for communication bus 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid with cable end for communication bus 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid without cable end for communication bus 1 x 0.2...1 x 1.5 mm², flexible with cable end for control 1 x 0.2...1 x 1.5 mm², flexible without cable end for control 1 x 0.2...1 x 1.5 mm², rigid with cable end for control 1 x 0.2...1 x 1.5 mm², rigid without cable end for control 2 x 0.2...2 x 1.5 mm², flexible with cable end for supply circuit 2 x 0.2...2 x 1.5 mm², flexible without cable end for supply circuit 2 x 0.2...2 x 1.5 mm², rigid with cable end for supply circuit 2 x 0.2...2 x 1.5 mm², rigid without cable end for supply circuit

Wire stripping length

Control: 10 mm Supply circuit: 7 mm Communication bus: 7 mm

Communication network type

RS485 Modbus RTU client/server SUB-D 9 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps

9 mm pitches

0 useful

height

22.5 mm

Width

359 mm

Depth

42 mm

Net weight

188 g

Provided equipment

Set of 1 bus connector Set of 1 power supply connector Set of 2 locking clips

Range compatibility

Acti 9 iTL auxiliary Linergy (Linergy FM) Acti 9 iOF+SD 24 Acti 9 iACT24 Acti 9 iATL24 PowerLogic pulse output meter Acti 9 RCA iC60 Acti 9 (Acti9 iCT) auxiliary Acti 9 (Acti9 iC60) Acti 9 (Acti9 iID) Acti 9 (Acti9 iSW-NA) Acti 9 (Acti9 iDPN Vigi) Acti 9 (Acti9 C40) Multi9 (Multi9 C60) Acti 9 (Acti9 DT40) Acti 9 (Acti9 DT60) Acti 9 (Acti9 I-NA) Acti 9 (Acti9 ITG40) Acti 9 (Acti9 iDPN) Acti 9 (Acti9 Reflex iC60) Ti24 connector

Commissioning interface

EcoStruxure Power Commission Web page

Market segment

Buildings Small commercial

Compatibility code

Acti 9 Smartlink

IP degree of protection

IP20

IK degree of protection

IK06 conforming to IEC 62262

Pollution degree

3

Electromagnetic compatibility

Resistance to electrostatic discharge (air discharge), class B, 8 kV, conforming to IEC 61000-4-2 Resistance to electrostatic discharge (contact discharge), class B, 4 kV, conforming to IEC 61000-4-2 Resistance to radiated electromagnetic fields (80 MHz...3 GHz), class A, 10 V/m, conforming to IEC 61000-4-3 Power supply: resistance to radiated electromagnetic fields (1.4…6 GHz), class A, 3 V/m, conforming to IEC 61000-4-3 Power supply: resistance to fast transient (5...100 kHz), class B, 2 kV, conforming to IEC 61000-4-4 Input/output: resistance to fast transient, class B, 1 kV, conforming to IEC 61000-4-4 Communication bus: resistance to fast transient (0.15...80 MHz), class B, 1 kV, conforming to IEC 61000-4-4 Conducted EMC (0.15...80 MHz), class A, 3 V, conforming to IEC 61000-4-6 Conducted emission (0.15...30 MHz), class B, conforming to IEC 61326-1 Conducted emission (0.15...30 MHz), class B, conforming to CISPR 11 Radiated emission (30...6000 MHz), class B, conforming to IEC 61326-1 Radiated emission (30...6000 MHz), class B, conforming to CISPR 11 Power supply: surges (DM coupling 42 Ohm), class B, 1 kV, conforming to IEC 61000-4-5 Power supply: surges (CM coupling 42 Ohm), class B, 2 kV, conforming to IEC 61000-4-5 Communication bus: surges (CM coupling 2 Ohm), class B, 1 kV, conforming to IEC 61000-4-5

Environmental characteristic

Corrosive 3C2 conforming to IEC 60721-3-3 Salt mist 2 conforming to IEC 60068-2-52

Vibration resistance

1 gn, amplitude = 3.5 mm (f = 5…300 Hz)10 cycles conforming to EN/IEC 60068-2-6

Shock resistance

15 gn for 11 ms conforming to IEC 60068-2-27

Fire resistance

Other parts: 650 °C ( 30 s ) conforming to IEC 60695-2-10 On connection terminals: 960 °C ( 30 s ) conforming to IEC 60695-2-10

Tropicalisation

2

Relative humidity

0…93 % at 40 °C

Operating altitude

0...2000 m

Ambient air temperature for operation

-25…60 °C

Ambient air temperature for storage

-40…85 °C

Standards

IEC 61010-2-201 IEC 61010-1

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

3.4 cm

Package 1 Width

6.4 cm

Package 1 Length

36.4 cm

Package 1 Weight

271.0 g

Unit Type of Package 2

S03

Number of Units in Package 2

32

Package 2 Height

30.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

9.063 kg

Warranty

18 months

Document Links

Catalogue page

Datasheet