Trade Price
POA
Per
1
Unit
Pack Quantity
This Acti 9 SmartLink Modbus Slave is a smart communication module with 11 channels. It communicates with the auxiliaries iACT24 for iCT contactors, iATL24 for iTL impulse relays, iOF+SD24 for iC60, iID, ARA, RCA & iSW-NA. It needs to be associated to a Master SmartLink SI B thanks to the Modbus RS485 connector. It is used to transfer data from Acti 9 devices to a PLC or network monitoring system thanks to the Ethernet connector. It communicates also with OF+SD24 for C60, C120, DPN, ID & C60H-DC, Ti24 for RCA iC60 & Reflex iC60. It is supplied with 1 power supply connector 24VDC, 2 bolts for mounting on Linergy FM80. The link is Modbus, RTU, RS485 serial connection. The transfer rate is self-adaptable from 9600 to 19200 baud. The Modbus addresing range is 1 to 99. It is a 4-pin connector type of bus. It is a plug-in connection. The maximum length of the bus is 1000m. The maximum cable length is 500m. The voltage power supply is 24VDC +/- 10%. The Maximum input current is 1,5A. The Maximum inrush current is 3A. The degree of protection is IP20. The pollution degree is 3. It complies with RoHS directive. The duration of saving memory is 10 years. The dimensions are (W) 359mm x (H) 23mm x (D) 42mm. The weigth is 195g. The operating temperature is -25°C to + 60°C and only +50°C if vertical mouting. The storage temperature is -40°C to + 80°C. This product complies with IEC/EN 61131-2 standard.
range of product
EcoStruxure
Product name
EcoStruxure I/O Smart Link
Product or component type
Smart communication module
Device short name
Smartlink Modbus
Application type
Load control Breaker status monitoring Basic energy metering E
Number max of connected devices
Up to 11 wired devices
group of channels
1 group of 11 digital channels
Maximum supply current
1.5 A
[Us] rated supply voltage
24 V DC +/- 20 %
Connectivity to devices
Digital input and output Pulse output meter
Communication service
Modbus server for RS485
Web server
BMS controller compatible
Web services
Web page
application specific I/O
Pulse totalising counter Pulse converter
Protection type
Against reverse polarity for auxiliary supply Against reverse polarity for input Overvoltage at 33 V DC for digital output
Immunity to microbreaks
10 ms
Reset
Factory reset on front face By booted push-button By address encoder By plug in, plug out the power supply
input/output type
2 inputs + 1 output per digital channel
Input type
Current sink for digital input, 24 V DC +/- 20 % at 2.5 mA
Maximum permanent current
5 mA for digital input
Electronic filtering time
2 ms for digital input from state 0 to state 1
Output type
Logic current source: 24 V - DC - 100 mA
Maximum voltage drop
<1 V at state 1 digital output
Inrush current
0.5 A for digital output 7 A for power supply
Local signalling
Communication: 1 LED (yellow) Status: 1 LED (green, orange and red)
Type of setting
Modbus address 01...99 for address encoders Reset for address encoders Reset for plug in, plug out the auxiliary supply
Mounting position
Horizontal and vertical on DIN rail
Colour
White (RAL 9003)
Location of connection
Front
Connections - terminals
Spring-loaded terminal Ti24 qty: 11 for digital input/output, ordered separately Plug-in connector qty: 1 for supply circuit Plug-in connector qty: 1 for communication bus
Clamping connection capacity
2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible with cable end for communication bus 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible without cable end for communication bus 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid with cable end for communication bus 2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid without cable end for communication bus 1 x 0.2...1 x 1.5 mm², flexible with cable end for control 1 x 0.2...1 x 1.5 mm², flexible without cable end for control 1 x 0.2...1 x 1.5 mm², rigid with cable end for control 1 x 0.2...1 x 1.5 mm², rigid without cable end for control 2 x 0.2...2 x 1.5 mm², flexible with cable end for supply circuit 2 x 0.2...2 x 1.5 mm², flexible without cable end for supply circuit 2 x 0.2...2 x 1.5 mm², rigid with cable end for supply circuit 2 x 0.2...2 x 1.5 mm², rigid without cable end for supply circuit
Wire stripping length
Control: 10 mm Supply circuit: 7 mm Communication bus: 7 mm
Communication network type
RS485 Modbus RTU client/server SUB-D 9 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
9 mm pitches
0 useful
height
22.5 mm
Width
359 mm
Depth
42 mm
Net weight
188 g
Provided equipment
Set of 1 bus connector Set of 1 power supply connector Set of 2 locking clips
Range compatibility
Acti 9 iTL auxiliary Linergy (Linergy FM) Acti 9 iOF+SD 24 Acti 9 iACT24 Acti 9 iATL24 PowerLogic pulse output meter Acti 9 RCA iC60 Acti 9 (Acti9 iCT) auxiliary Acti 9 (Acti9 iC60) Acti 9 (Acti9 iID) Acti 9 (Acti9 iSW-NA) Acti 9 (Acti9 iDPN Vigi) Acti 9 (Acti9 C40) Multi9 (Multi9 C60) Acti 9 (Acti9 DT40) Acti 9 (Acti9 DT60) Acti 9 (Acti9 I-NA) Acti 9 (Acti9 ITG40) Acti 9 (Acti9 iDPN) Acti 9 (Acti9 Reflex iC60) Ti24 connector
Commissioning interface
EcoStruxure Power Commission Web page
Market segment
Buildings Small commercial
Compatibility code
Acti 9 Smartlink
IP degree of protection
IP20
IK degree of protection
IK06 conforming to IEC 62262
Pollution degree
3
Electromagnetic compatibility
Resistance to electrostatic discharge (air discharge), class B, 8 kV, conforming to IEC 61000-4-2 Resistance to electrostatic discharge (contact discharge), class B, 4 kV, conforming to IEC 61000-4-2 Resistance to radiated electromagnetic fields (80 MHz...3 GHz), class A, 10 V/m, conforming to IEC 61000-4-3 Power supply: resistance to radiated electromagnetic fields (1.4…6 GHz), class A, 3 V/m, conforming to IEC 61000-4-3 Power supply: resistance to fast transient (5...100 kHz), class B, 2 kV, conforming to IEC 61000-4-4 Input/output: resistance to fast transient, class B, 1 kV, conforming to IEC 61000-4-4 Communication bus: resistance to fast transient (0.15...80 MHz), class B, 1 kV, conforming to IEC 61000-4-4 Conducted EMC (0.15...80 MHz), class A, 3 V, conforming to IEC 61000-4-6 Conducted emission (0.15...30 MHz), class B, conforming to IEC 61326-1 Conducted emission (0.15...30 MHz), class B, conforming to CISPR 11 Radiated emission (30...6000 MHz), class B, conforming to IEC 61326-1 Radiated emission (30...6000 MHz), class B, conforming to CISPR 11 Power supply: surges (DM coupling 42 Ohm), class B, 1 kV, conforming to IEC 61000-4-5 Power supply: surges (CM coupling 42 Ohm), class B, 2 kV, conforming to IEC 61000-4-5 Communication bus: surges (CM coupling 2 Ohm), class B, 1 kV, conforming to IEC 61000-4-5
Environmental characteristic
Corrosive 3C2 conforming to IEC 60721-3-3 Salt mist 2 conforming to IEC 60068-2-52
Vibration resistance
1 gn, amplitude = 3.5 mm (f = 5…300 Hz)10 cycles conforming to EN/IEC 60068-2-6
Shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
Fire resistance
Other parts: 650 °C ( 30 s ) conforming to IEC 60695-2-10 On connection terminals: 960 °C ( 30 s ) conforming to IEC 60695-2-10
Tropicalisation
2
Relative humidity
0…93 % at 40 °C
Operating altitude
0...2000 m
Ambient air temperature for operation
-25…60 °C
Ambient air temperature for storage
-40…85 °C
Standards
IEC 61010-2-201 IEC 61010-1
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3.4 cm
Package 1 Width
6.4 cm
Package 1 Length
36.4 cm
Package 1 Weight
271.0 g
Unit Type of Package 2
S03
Number of Units in Package 2
32
Package 2 Height
30.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
9.063 kg
Warranty
18 months