ATV930C11N4

ATV930 110KW 400V VSD WITH BRAKE

Trade Price

POA

Per

1

Unit

EA

Pack Quantity

1

ATV930C11N4

Technical Specifications

Range of product

Altivar Process ATV900

Device application

Industrial application

Product or component type

Variable speed drive

Product destination

Synchronous motors Asynchronous motors

Product specific application

Process for industrial

Variant

Standard version With braking chopper

Network number of phases

3 phases Single phase

Mounting mode

Wall mount

Communication port protocol

Ethernet IP/Modbus TCP Modbus

[Us] rated supply voltage

380...480 V - 15...10 %

Motor power kW

110.0 kW for normal duty 90.0 kW for heavy duty

Motor power hp

150.0 hp for normal duty 125.0 hp for heavy duty

Continuous output current

211 A at 4 kHz for normal duty 173 A at 4 kHz for heavy duty

EMC filter

Integrated With EMC plate option

IP degree of protection

IP21

Degree of protection

UL type 1

option module

Slot A: communication module for Profibus DP V1 Slot A: communication module for PROFINET Slot A: communication module for DeviceNet Slot A: communication module for EtherCAT Slot A: communication module for CANopen daisy chain RJ45 Slot A: communication module for CANopen SUB-D 9 Slot A: communication module for CANopen screw terminals Slot A/slot B/slot C: digital and analog I/O extension module Slot A/slot B/slot C: output relay extension module Slot B: 5/12 V digital encoder interface module Slot B: analog encoder interface module Slot B: resolver encoder interface module

Asynchronous motor control profile

Constant torque standard Variable torque standard Optimized torque mode

Synchronous motor control profile

Permanent magnet motor Synchronous reluctance motor

Maximum output frequency

599 Hz

Switching frequency

1...8 kHz adjustable 2.5...8 kHz with derating factor

Nominal switching frequency

2.5 kHz

Line current

201.0 A at 380 V (normal duty) 170.0 A at 380 V (heavy duty) 165.0 A at 480 V (normal duty) 143.0 A at 480 V (heavy duty)

Apparent power

121.8 kVA at 380...480 V (normal duty) 102.6 kVA at 380...480 V (heavy duty)

Maximum transient current

253 A during 60 s (normal duty) 259.5 A during 60 s (heavy duty)

Network frequency

50...60 Hz

Prospective line Isc

50 kA

Discrete input number

10

Relay output type

Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles

Physical interface

Ethernet 2-wire RS 485

Connector type

2 RJ45 1 RJ45

Method of access

Slave Modbus TCP

Transmission rate

10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial

Transmission frame

RTU

Number of addresses

1…247 for Modbus serial

Data format

8 bits, configurable odd, even or no parity for Modbus serial

Type of polarization

No impedance for Modbus serial

4 quadrant operation possible

True

Acceleration and deceleration ramps

Linear adjustable separately from 0.01...9999 s S, U or customized

Motor slip compensation

Adjustable Automatic whatever the load Can be suppressed Not available in permanent magnet motor law

Braking to standstill

By DC injection

Brake chopper integrated

True

Maximum input current

201.0 A

Maximum output voltage

480.0 V

Relative symmetric network frequency tolerance

5 %

Base load current at high overload

173.0 A

Base load current at low overload

211.0 A

With safety function Safely Limited Speed (SLS)

True

With safety function Safe brake management (SBC/SBT)

True

With safety function Safe Operating Stop (SOS)

False

With safety function Safe Position (SP)

False

With safety function Safe programmable logic

False

With safety function Safe Speed Monitor (SSM)

False

With safety function Safe Stop 1 (SS1)

True

With sft fct Safe Stop 2 (SS2)

False

With safety function Safe torque off (STO)

True

With safety function Safely Limited Position (SLP)

False

With safety function Safe Direction (SDI)

False

Protection type

Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive

Quantity per set

1

Width

320 mm

height

1205 mm

Depth

393 mm

Net weight

104 kg

Electrical connection

Line side: screw terminal 2 x 50...3 x 120 mm²/2 x AWG 1/0...2 x 300 kcmil DC bus: screw terminal 0.5...1.5 mm²/AWG 20...AWG 16 Control: screw terminal 0.5...1.5 mm²/AWG 20...AWG 16

Local signalling

Local diagnostic: 3 LEDs (mono/dual colour) 5 LEDs (dual colour) 2 LEDs (dual colour) 1 LED (red)

Isolation

Between power and control terminals

Operating position

Vertical +/- 10 degree

product certifications

UL CSA TÜV

Marking

CE

standards

UL 508C EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Maximum THDI

<48 % full load conforming to IEC 61000-3-12

Assembly style

Enclosed

Electromagnetic compatibility

Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

Environmental class (during operation)

Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3

Maximum acceleration under shock impact (during operation)

150 m/s² at 11 ms

Maximum acceleration under vibrational stress (during operation)

10 m/s² at 13...200 Hz

Maximum deflection under vibratory load (during operation)

1.5 mm at 2...13 Hz

Permitted relative humidity (during operation)

Class 3K5 according to EN 60721-3

Overvoltage category

III

Regulation loop

Adjustable PID regulator

Insulation resistance

> 1 MOhm 500 V DC for 1 minute to earth

Noise level

69.9 dB

Vibration resistance

1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6

Shock resistance

6 gn for 11 ms conforming to IEC 60068-2-27

Environmental characteristic

Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3

Relative humidity

5…95 % without condensation conforming to IEC 60068-2-3

Ambient air temperature for operation

-15…50 °C (without derating) 50…60 °C (with derating factor)

Pollution degree

2

Ambient air transport temperature

-25…70 °C

Ambient air temperature for storage

-25…70 °C

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

68.000 cm

Package 1 Width

48.500 cm

Package 1 Length

144.500 cm

Package 1 Weight

128.000 kg

Warranty

18 months