Trade Price
POA
Per
1
Unit
Pack Quantity
This sinus filter is an option for variable speed drives of Altivar Process ATV600 / ATV900 range. Its rated current is equal to 305A. It is used as an output filter (between drive output and motor) and enables your variable speed drive to run with motor cables longer than the maximum permitted lengths. Its protection index is IP00. It weighs 134kg. It is used for applications requiring long cable runs, motors connected in parallel, submersible pumps sensitive to dv/dt, an intermediate transformer between the drive and the motor.
Product or component type
Sinus filter
range compatibility
Altivar Process ATV900 Altivar Process ATV600
Product specific application
Output filter
Maximum motor cable length
1000 m unshielded cable 500 m shielded cable
[In] rated current
305 A
Thermal losses
676 W at 4 kHz
Product compatibility
Variable speed drive ATV630 wall mount, motor: 55 kW, 380...480 V Variable speed drive ATV630 wall mount, motor: 110 kW, 380...480 V Variable speed drive ATV630 wall mount, motor: 132 kW, 200...240 V Variable speed drive ATV630 wall mount, motor: 160 kW, 380...480 V Variable speed drive ATV930 wall mount, motor: 55 kW, 380...480 V Variable speed drive ATV930 wall mount, motor: 110 kW, 380...480 V Variable speed drive ATV930 wall mount, motor: 132 kW, 200...240 V Variable speed drive ATV930 wall mount, motor: 160 kW, 380...480 V
Electrical connection
M10 copper bar, connection capacity: 300 mm² / 500 kcmil
Operating altitude
<= 1000 m without current derating 1000...4000 m with current derating 1 % per 100 m
Switching frequency
2.5...6 kHz
Maximum output frequency
100 Hz
Maximum voltage drop at rated load
8 %
Permissible voltage
480 V AC
Max current
1.20 x nominal current (duration = 60 s)
Width
460 mm
height
370 mm
Depth
565 mm
Net weight
131 kg
IP degree of protection
IP00
Environmental characteristic
Biological pollution resistance class 3B1 conforming to IEC 60721-3-3 Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3
Pollution degree
3 conforming to IEC 61800-5-1
Relative humidity
5…95 % without condensation
Ambient air temperature for operation
50…60 °C (with current derating 1.5 % per °C) -15…50 °C (without current derating)
Ambient air temperature for storage
-40…70 °C
Mechanical robustness
Shocks class 3M4 conforming to IEC 60721-3-3 Vibrations class 3M4 conforming to IEC 60721-3-3
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
56.500 cm
Package 1 Width
46.000 cm
Package 1 Length
37.000 cm
Package 1 Weight
138.500 kg