VW3A5307

OUTPUT DV/DT FILTER IP00 300A

Trade Price

POA

Per

1

Unit

Pack Quantity

VW3A5307

Information

This dv/dt filter is an option for variable speed drives of Altivar Process ATV600 / ATV900 range. Its rated current is equal to 305A. It is used as an output filter (between drive output and motor) and enables your variable speed drive to run with motor cables longer than the maximum permitted lengths. Its protection index is IP00. It weighs 40kg. It is used to limit overvoltages at the motor terminals, filter interference and reduce motor earth leakage current.

Technical Specifications

Product or component type

Dv/dt filter

range compatibility

Easy Altivar 610 Altivar Process ATV900 Altivar Process ATV600

Product specific application

Output filter

[In] rated current

305 A

Product compatibility

ATV630 variable speed drive wall mount - 110 kW, 380...480 V ATV630 variable speed drive wall mount - 132 kW, 380...480 V ATV630 variable speed drive wall mount - 160 kW, 380...480 V ATV630 variable speed drive wall mount - 55 kW, 200...240 V ATV630 variable speed drive wall mount - 75 kW, 200...240 V ATV610 variable speed drive - 110 kW, 380...415 V ATV610 variable speed drive - 132 kW, 380...415 V ATV610 variable speed drive - 160 kW, 380...415 V ATV930 variable speed drive wall mount - 110 kW, 380...480 V ATV930 variable speed drive wall mount - 132 kW, 380...480 V ATV930 variable speed drive wall mount - 160 kW, 380...480 V ATV930 variable speed drive wall mount - 55 kW, 200...240 V ATV930 variable speed drive wall mount - 75 kW, 200...240 V

nedded quantity

1

Electrical connection

Copper bar M10, connection capacity: 300 mm² / 500 kcmil

Maximum motor cable length

500 m unshielded cable 300 m shielded cable

dv/dt

6000 V/µs max at 200...240 V 6000 V/µs max at 380...480 V

Thermal losses

287 W at 4 kHz

maximum drive output frequency

100 Hz

Ambient air temperature for operation

-10…50 °C (without current derating) 50…60 °C (with current derating 1.5 % per °C)

Operating altitude

0...1000 m without current derating 1000...4000 m with current derating 1 % per 100 m

Width

420 mm

height

360 mm

Depth

270 mm

Net weight

40 kg

IP degree of protection

IP00

Ambient air temperature for storage

-40…70 °C

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

43.500 cm

Package 1 Width

45.000 cm

Package 1 Length

79.000 cm

Package 1 Weight

53.000 kg

Warranty

18 months

Document Links

Datasheet