METSEPM5350

PM5350 POWER METER WITHTHD.ALARMING

Trade Price

£545.59

Per

1

Unit

EA

Pack Quantity

1

METSEPM5350

Information

This device is a flush-mount energy meter with a 96mm by 96mm backlit LCD display. The meter provides Class 0.5S accuracy per IEC 62053-22 standard and 32 samples per cycle. The meter will measure Energy, Active and Reactive Power, Voltage, Current, Frequency, Power Factor and up to 15th Harmonic. Include a non-volatile memory for several parameters and alarms. The meter will function in a 50Hz or 60Hz network and accepts supply voltage ranging from 85 to 265 VAC and 100 to 300 VDC. Line rated current for this meter is 1A or 5A input and will support Single Phase and Neutral, Three Phase, or Three Phase and Neutral configurations. The range of measurement voltage between Phases is 20V AC to 480V AC, CAT III or 20V AC to 690V AC, CAT II at 45 Hz to 70 Hz. The range of measurement voltage between Phase and Neutral is 20V AC to 277V AC, CAT III or 20V AC to 400V AC, CAT II at 45 Hz to 70 Hz. Communication protocol is Modbus RTU and ASCII 2 wires with RS485 port support. The meter also has four digital inputs and dual relay outputs. Product dimensions are as follows: width 3.78 inches (96 millimetres), depth 2.24 inches (57 millimetres), height 3.78 inches (96 millimetres) and product weight 8.8 onces (250 g).

Technical Specifications

Range

PowerLogic

Product name

PowerLogic PM5350

Device short name

PM5350

Product or component type

Power meter

Power quality analysis

total demand distortion total harmonic distortion

Device application

Power monitoring

Type of measurement

Current Voltage Frequency Power factor Energy Phase angle Apparent power Active power Reactive power

supply voltage

85...265 V AC 45...65 Hz 100...300 V DC

Network frequency

50 Hz 60 Hz

[In] rated current

5 A 1 A

type of network

1P + N 3P + N 3P

Maximum power consumption in VA

11.9 VA

Ride-through time

100 ms 120 V AC typical 400 ms 230 V AC typical 50 ms 125 V DC typical

Display type

Monochrome graphic LCD

Display resolution

6 lines

Sampling rate

32 samples/cycle

Measurement current

5…9000 mA

Analogue input type

Current 0.05...9 A (impedance <= 0.3 mOhm) Voltage (impedance 10 MOhm)

Measurement voltage

35…480 V AC 45...65 Hz phase to phase 20…277 V AC phase to neutral

Frequency measurement range

45…70 Hz

Number of inputs

4 digital

Measurement accuracy

Current +/- 0.3 % Voltage +/- 0.3 % Frequency +/- 0.05 % Power factor +/- 0.005 Active energy +/- 0.5 % Reactive energy +/- 2 % Active power +/- 0.5 % Apparent power +/- 0.5 % Apparent energy +/- 0.5 % Reactive power +/- 2 %

Accuracy class

Class 0.5S active energy conforming to IEC 62053-22 Class 0.5 active energy conforming to IEC 61557-12 Class 2 reactive energy conforming to IEC 62053-23 Class 2 reactive energy conforming to IEC 61557-12 Class 0.5 power conforming to IEC 61557-12

Number of outputs

2 relay

Information displayed

Tariff (4)

Communication port protocol

JBUS Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds

Communication port support

Terminal block: RS485

data recording

Min/max of instantaneous values Alarms

Connections - terminals

Voltage circuit: screw terminal block4 Control circuit: screw terminal block2 Current transformer: screw terminal block6 Input/output circuit: screw terminal block6 Relay output: screw terminal block4 Ethernet network: RJ45 connector

Mounting mode

Flush-mounted

Type of installation

Indoor installation

Standards

IEC 61010-1

Product certifications

CE CULus

Width

96 mm

Depth

44 mm

Height

96 mm

Net weight

0.25 kg

Electromagnetic compatibility

Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3 Electrostatic discharge conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Immunity to impulse waves conforming to IEC 61000-4-12 Conducted and radiated emissions class A conforming to EN 55011 Limits for harmonic current emissions conforming to IEC 61000-3-2

Overvoltage category

III

IP degree of protection

IP30 rear: conforming to IEC 60529 IP54 display: conforming to IEC 60529

Relative humidity

5…95 % at 50 °C non-condensing

Pollution degree

2

Ambient air temperature for operation

-25…70 °C meter -20…70 °C display -25…-20 °C (with reduced performance) display

Ambient air temperature for storage

-40…85 °C

Operating altitude

<= 3000 m

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

11.200 cm

Package 1 Width

12.500 cm

Package 1 Length

12.700 cm

Package 1 Weight

346.000 g

Unit Type of Package 2

S03

Number of Units in Package 2

12

Package 2 Height

30.000 cm

Package 2 Width

30.000 cm

Package 2 Length

40.000 cm

Package 2 Weight

4.962 kg

Warranty

18 months

Document Links

Datasheet