A9D17332

A9 IC60 RCBO 3P 32A 30mA C A

Trade Price

POA

Per

1

Unit

EA

Pack Quantity

1

A9D17332

Information

This Acti 9 iC60 RCBO is a modular and reliable residual current breaker with overcurrent protection (RCBO). It is a 3P RCBO with 3 protected poles, rated current is 32A, and operating voltage is 220VAC to 240VAC. Breaking capacity at 220VAC to 240VAC is 10kA according to EN/IEC 61009-2-1. Breaking capacity at 220VAC to 240VAC is 15kA according to EN/IEC 60947-2. Electrical endurance goes up to 10000 cycles, and mechanical endurance goes up to 20000 cycles. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. Device location in system is outgoer, and the earth leakage protection class is type A. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1.

Technical Specifications

Range

Acti9

Product name

Acti9 iC60 RCBO

Product or component type

Residual current breaker with overcurrent protection (RCBO)

Device short name

iC60 RCBO

Device application

Distribution

Poles description

3P

Number of protected poles

3

[In] rated current

32 A

Network type

AC

Trip unit technology

Thermal-magnetic

Curve code

C

Earth-leakage sensitivity

30 mA

earth-leakage protection time delay

Instantaneous

Earth-leakage protection class

Type A

Breaking capacity

10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2

Suitability for isolation

No conforming to IEC 60947-1

Quality labels

NF KEMA-KEUR VDE IMQ

Complementary

Outgoer

Network frequency

50 Hz

[Ue] rated operational voltage

220...240 V AC 50 Hz

Magnetic tripping limit

5...10 x In

Residual current tripping technology

Voltage independent

[Ics] rated service breaking capacity

7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2

Rated breaking and making capacity

Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1

Limitation class

1 conforming to EN/IEC 61009-2-1

[Ui] rated insulation voltage

500 V AC 50 Hz

[Uimp] rated impulse withstand voltage

4 kV

Surge current

250 A

Contact position indicator

No

Control type

Toggle

Local signalling

ON, OFF, fault trip

Mounting mode

Clip-on

mounting support

DIN rail

Comb busbar and distribution block compatibility

Top or bottom: YES Bottom: biconnect

Connection pitch

9 mm between poles

9 mm pitches

6

height

86 mm

Width

54 mm

Depth

78 mm

Net weight

334 g

Colour

White

Mechanical durability

20000 cycles

Electrical durability

10000 cycles

Connections - terminals

Tunnel type terminal top or bottom 1…35 mm² rigid Tunnel type terminal top or bottom 1…25 mm² flexible Tunnel type terminal top or bottom 1…25 mm² flexible with ferrule

Wire stripping length

12 mm for top or bottom connection

Tightening torque

2 N.m

earth-leakage protection

Integrated

Standards

EN/IEC 60947-2 EN/IEC 61009-2-1

IP degree of protection

IP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529

Overvoltage category

III conforming to IEC 60364

Electromagnetic compatibility

8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1

Tropicalisation

2

Relative humidity

95 % at 55 °C

Ambient air temperature for operation

-25…60 °C

Ambient air temperature for storage

-40…70 °C

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

8 cm

Package 1 Width

5.7 cm

Package 1 Length

9.8 cm

Package 1 Weight

340 g

Unit Type of Package 2

BB1

Number of Units in Package 2

4

Package 2 Height

9.8 cm

Package 2 Width

11.5 cm

Package 2 Length

25 cm

Package 2 Weight

1.433 kg

Unit Type of Package 3

S03

Number of Units in Package 3

24

Package 3 Height

30 cm

Package 3 Width

30 cm

Package 3 Length

40 cm

Package 3 Weight

9.17 kg

Warranty

18 months

Document Links

Datasheet