Trade Price
POA
Per
1
Unit
EA
Pack Quantity
1
This Acti9 Active iCV40 ARC product is an arc fault detection RCBO. It is a 1P+N with 1 protected pole, 32A In rated current and C tripping curve. The earth leakage protection class is A-SI type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The rated short circuit breaking capacity goes up to 10000A at 230VAC conforming to EN/IEC 61009-2-1 standard and 10kA at 230VAC conforming to EN/IEC60947-2. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. The Acti9 Active products communicate with the gateway EcoStruxure Panel Server Entry, Universal and Advanced. Its pre alarming system can prevent any overload, earth leakage and overvoltage. It can also measure the voltage, the current and the power. Its 2 unique VisiTrip indicators reduce intervention time by showing the faulty circuit and identifying quickly the type of default. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 250VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 2. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 91mm x (D)73mm. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. This product is compliant with EN/IEC 60898-1, EN/IEC 60947-2, EN/IEC 62606, EN/IEC 61009-1 and EN/IEC 61009-2-1 standard.
Range
Acti9
Product name
Acti9 iCV40 ARC
Product or component type
Arc fault detection RCBO
Product specific application
Arc fault detection
Standards
EN/IEC 62606 EN/IEC 61009-1 EN/IEC 60947-2 EN/IEC 61009-2-1 BS EN 62606
Device short name
iCV40 ARC
Poles description
1P + N
Number of protected poles
1
Curve code
C
Breaking capacity
10000 A Icn at 230 V AC 50 Hz conforming to IEC 61009-2-1 10 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2
Rated breaking and making capacity
Idm 3000 A at 230 V AC 50 Hz conforming to IEC 61009-2-1
Neutral position
Left
Network type
AC
earth-leakage protection time delay
Instantaneous
Earth-leakage protection class
Type A-SI (Super Immunised)
electrical data recording
Date and time Maintenance indicators
Concentrator compatibility
EcoStruxure Panel Server Advanced EcoStruxure Panel Server Entry EcoStruxure Panel Server Universal
Event management
Overvoltage Earth leakage Overload
Type of measurement
Voltage Active power Current Power factor
Accuracy
Voltage: +/- 2 % Current: +/- 2 % Power: +/- 5 %
Suitability for isolation
Yes
Residual current tripping technology
Voltage independent
Trip unit technology
Thermal-magnetic
earth-leakage protection
Integrated
[In] rated current
32 A
Network frequency
50 Hz
[Ue] rated operational voltage
230 V AC 50 Hz
device location in system
Outgoer
Magnetic tripping limit
5...10 x In
[Ics] rated service breaking capacity
7500 A AC 50 Hz conforming to IEC 61009-2-1 5 kA AC 50 Hz conforming to IEC 60947
Limitation class
3
[Ui] rated insulation voltage
250 V AC 50 Hz between phase and neutral
Threshold tripping voltage
275 V for +/- 5 V
[Uimp] rated impulse withstand voltage
4 kV
Contact position indicator
Yes
control type
Toggle
local signalling
ON, OFF, fault trip LED arc fault diagnostic
Mounting mode
Clip-on
mounting support
DIN rail
Colour
White (RAL 9003)
Mechanical durability
20000 cycles
Electrical durability
10000 cycles 230 V AC 50 Hz
Overvoltage category
III
Locking options description
Padlocking device
Cable entry
Top and bottom
Connections - terminals
Tunnel type terminal 1…16 mm² rigid Tunnel type terminal 1…10 mm² flexible
Wire stripping length
14 mm
Tightening torque
2 N.m
Comb busbar and distribution block compatibility
YES
9 mm pitches
4
height
91 mm
Width
36 mm
Depth
73 mm
Net weight
220 g
Earth-leakage sensitivity
30 mA
IP degree of protection
IP20 conforming to IEC 60529
Pollution degree
2 conforming to EN/IEC 62606
Tropicalisation
Severity B conforming to IEC 60068-2-30 for 28 d
Relative humidity
95 % at 55 °C
Operating altitude
2000 m
ambient air temperature for operation
-25…40 °C
Ambient air temperature for storage
-40…80 °C
product certifications
UKCA
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.4 cm
Package 1 Width
8.4 cm
Package 1 Length
11.3 cm
Package 1 Weight
246.0 g
Unit Type of Package 2
S02
Number of Units in Package 2
24
Package 2 Height
15.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
6.212 kg
Warranty
18 months
Datasheet