APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (36) C13 & (6) C19, and the cable length is 3m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Presentation
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (36) C13 & (6) C19, and the cable length is 3m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower the total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra-low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Lead time
Usually in Stock
Main Input Voltage
200 V 208 V 230 V
PDU type
Metered
Main Output Voltage
230 V
Input Connection Type
IEC 60309 32 A 2P + E
Number of rack unit
0U
Cable length
3.00 m
Number of cables
1
Provided equipment
Installation guide Rack mounting brackets Serial configuration cable Safety guide
Colour
Black
height
179.1 cm
Width
5.6 cm
Depth
4.4 cm
Net weight
6.93 kg
Mounting location
Side
Mounting preference
No preference
Mounting mode
Rack-mounted
USB compatible
No
Mounting position
Vertical
Permissible voltage
220…240 V
Max line current
32 A
Input current limits
32 A
Load capacity
7400 VA
Network frequency
50/60 Hz
Number of power socket outlets
36 IEC 60320 C13 6 IEC 60320 C19
product certifications
VDE
standards
IEC 60950
Ambient air temperature for operation
-5…60 °C
Relative humidity
5…95 %
Operating altitude
0...10000 ft
Ambient air temperature for storage
-25…65 °C
Storage Relative Humidity
5…95 %
Storage altitude
0.00…15240.00 m
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
200 cm
Package 1 Width
10.7 cm
Package 1 Length
16.2 cm
Package 1 Weight
8.56 kg
Warranty
2 years repair or replace
Datasheet