Trade Price
£126.87
Per
1
Unit
EA
Pack Quantity
1
TeSys LR97D electronic overcurrent relay, 7A/690V, to be supplied with 48V AC/DC, for protection of motors with a rated current 1.2-6A. It provides 3 dials to adjust the protection, LOAD (1.2-7A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. The settings include selectors for 1-phase/3-phase motors and manual/automatic reset, and the device has a reset button, a test/stop button, 2 LED indicators (Run/Trip), 2 auxiliary contacts 1NO/NC for fault signalling. Settings can be locked by sealing the transparent cover. For direct attachement to the bottom terminals of a 3-pole contactor LC1D09-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs/Reach.
Device short name
LR97
Product or component type
Electronic overcurrent relay
Device application
Protection
Relay application
Locked rotor, mechanical jamming I > 3 x Isetting Sensitivity to phase failure Overload Imax > Isetting
Product compatibility
LC1D09...D38
Network type
DC AC
[Us] rated supply voltage
48 V AC/DC
Thermal protection adjustment range
1.2…7 A
[Ue] rated operational voltage
600 V AC 50/60 Hz for power circuit conforming to CSA 600 V AC 50/60 Hz for power circuit conforming to UL 690 V AC 50/60 Hz for power circuit conforming to IEC 60947-4-1
Quantity per set
Set of 10
Network frequency
50...60 Hz
Mounting support
Direct on contactor Rail
Tripping threshold
1.2...6 A
Surge withstand
6 kV conforming to IEC 61000-4-5
Contacts type and composition
1 C/O
[Ith] conventional free air thermal current
3 A for control circuit
Protection type
BS fuse 3 A - for control circuit GB2 circuit breaker 3 A - for control circuit GG fuse 3 A - for control circuit
Maximum power
28 W at 110 V DC conforming to IEC 60947 28 W at 220 V DC conforming to IEC 60947 55 W at 24 V DC conforming to IEC 60947 55 W at 48 V DC conforming to IEC 60947 140 VA at 48 V AC conforming to IEC 60947 360 VA at 110 V AC conforming to IEC 60947 360 VA at 220 V AC conforming to IEC 60947 70 VA at 24 V AC conforming to IEC 60947
[Ui] rated insulation voltage
Power circuit: 600 V conforming to CSA Power circuit: 600 V conforming to UL Power circuit: 690 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage
6 kV
Phase failure sensitivity
< 3 s
Reset
Automatic reset 120 s fixed Electrical by interruption of power supply for minimum 0.1 s Manual reset
Time range
0.2...10 s - O-time knob 0.3...10 s - O-time knob 0.5..30 s - D-time knob
Signalling function
2 LEDs
Connections - terminals
Control circuit: cable 1 x 1…25 mm²flexible with cable end Control circuit: cable 1 x 1…25 mm²flexible without cable end Power circuit: cable 1 x 1…4 mm²flexible with cable end Power circuit: cable 1 x 1.5…10 mm²flexible without cable end Power circuit: lug-clamp 1 x 1…4 mm²flexible with cable end Power circuit: lug-clamp 1 x 1.5…10 mm²flexible without cable end Control circuit: cable 2 x 1…25 mm²flexible with cable end Control circuit: cable 2 x 1…25 mm²flexible without cable end Control circuit: lug-clamp 1 x 1…25 mm²flexible with cable end Control circuit: lug-clamp 1 x 1…25 mm²flexible without cable end Control circuit: lug-clamp 2 x 1…25 mm²flexible with cable end Control circuit: lug-clamp 2 x 1…25 mm²flexible without cable end
Tightening torque
Control circuit: 0.6...1.2 N.m on lug-clamp Power circuit: 2 N.m on cable
height
67.5 mm
Width
45 mm
Depth
67.5 mm
Net weight
0.172 kg
Standards
IEC 60255-6 IEC 60947
product certifications
UL CSA GOST
Protective treatment
TH conforming to IEC 60068
IP degree of protection
IP20 conforming to IEC 60529
Ambient air temperature for operation
-25…60 °C conforming to IEC 60947-4-1
Ambient air temperature for storage
-30…80 °C
Operating altitude
2000 m
Fire resistance
850 °C conforming to IEC 60695-2-1
Shock resistance
15 gn 11 ms conforming to IEC 60068-2-7
Vibration resistance
4 gn conforming to IEC 60068-2-6
Dielectric strength
2 V 50 Hz conforming to IEC 60255-5
Resistance to electrostatic discharge
6 kV in indirect mode 8 kV in air
Resistance to radiated fields
10 V/m level 3
Resistance to fast transients
2 kV
Disturbance radiated/conducted
10 V conforming to EN 61000-4-6 Class A conforming to EN 55011
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
5.0 cm
Package 1 Width
6.9 cm
Package 1 Length
7.6 cm
Package 1 Weight
180.0 g
Unit Type of Package 2
S02
Number of Units in Package 2
24
Package 2 Height
15.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
4.775 kg
Warranty
18 months
Datasheet
Technical Data