LC1F780

780A 3p contactor without coil

Trade Price

£11,737.57

Per

1

Unit

EA

Pack Quantity

1

LC1F780

Information

TeSys F contactor, 3 poles (3NO), 780A/1000V AC-3, for motor applications up to 400kW@400V. Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs. For high operating rates until 600 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Technical Specifications

Range

TeSys

Product name

TeSys F

Product or component type

Contactor

Device short name

LC1F

contactor application

Resistive load Motor control

utilisation category

AC-4 AC-3 AC-1

Poles description

3P

power pole contact composition

3 NO

[Ue] rated operational voltage

<= 1000 V AC 50/60 Hz <= 460 V DC

[Ie] rated operational current

780 A (at <55 °C) at <= 440 V AC AC-3 1600 A (at <40 °C) at <= 440 V AC AC-1

Motor power kW

450 kW at 1000 V AC 50/60 Hz (AC-3) 400 kW at 380...400 V AC 50/60 Hz (AC-3) 425 kW at 415 V AC 50/60 Hz (AC-3) 425 kW at 440 V AC 50/60 Hz (AC-3) 450 kW at 500 V AC 50/60 Hz (AC-3) 220 kW at 220...240 V AC 50/60 Hz (AC-3) 475 kW at 660...690 V AC 50/60 Hz (AC-3) 110 kW at 400 V AC 50/60 Hz (AC-4)

[Uc] control circuit voltage

110...500 V AC 40...400 Hz with LX1/LX9 coil 48...440 V DC with LX4 coil

[Uimp] rated impulse withstand voltage

8 kV

Overvoltage category

III

[Ith] conventional free air thermal current

1600 A (at 40 °C)

Irms rated making capacity

7800 A AC conforming to IEC 60947-4-1

Rated breaking capacity

6240 A conforming to IEC 60947-4-1

[Icw] rated short-time withstand current

3000 A 40 °C - 3 min 6250 A 40 °C - 10 s 5600 A 40 °C - 30 s 4600 A 40 °C - 1 min 2200 A 40 °C - 10 min

Associated fuse rating

800 A aM at <= 440 V 1600 A gG at <= 440 V

Average impedance

0.1 mOhm - Ith 1600 A 50 Hz

[Ui] rated insulation voltage

1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C

Power dissipation per pole

60 W AC-3 250 W AC-1

Control circuit voltage limits

Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil Drop-out: 0.2...0.4 Uc AC 40...400 Hz with LX1/LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.2...0.4 Uc DC with LX4 coil

Heat dissipation

22 W

Operating time

40...80 ms closing for with LX1/LX9 coil 130...230 ms opening for with LX1/LX9 coil 70...80 ms closing for with LX4 coil 100...130 ms opening for with LX4 coil

mounting support

Plate

standards

IEC 60947-1 IEC 60947-4-1 EN 60947-1 JIS C8201-4-1 EN 60947-4-1

product certifications

UL LROS (Lloyds register of shipping) RINA DNV CCC BV CB ABS UKCA

Connections - terminals

Power circuit: bar 2 cable(s) - busbar cross section: 100 x 5 mm Power circuit: bolted connection Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm² Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²

Tightening torque

Power circuit: 58 N.m Control circuit: 1.2 N.m

Mechanical durability

5 Mcycles

Inrush power in VA

1900…2300 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 1960…2420 VA (at 20 °C)with LX4 coil

Hold-in power consumption in VA

44…55 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 42…52 VA (at 20 °C)with LX4 coil

Maximum operating rate

600 cyc/h 55 °C

Compatibility code

LC1F

IP degree of protection

IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106

Protective treatment

TH

Ambient air temperature for operation

-5…55 °C

Ambient air temperature for storage

-60…80 °C

Permissible ambient air temperature around the device

-40…70 °C

Operating altitude

3000 m without derating

Mechanical robustness

Vibrations contactor open: 2.5 Gn, 5...300 Hz Vibrations contactor closed: 5.5 Gn, 5...300 Hz Shocks contactor open: 5 Gn for 1/2 sine wave (11 ms) Shocks contactor closed: 15 Gn for 1/2 sine wave (11 ms)

height

434 mm

Width

702 mm

Depth

255 mm

Net weight

48 kg

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

31.500 cm

Package 1 Width

41.000 cm

Package 1 Length

90.500 cm

Package 1 Weight

41.000 kg

Unit Type of Package 2

P12

Number of Units in Package 2

2

Package 2 Height

75.000 cm

Package 2 Width

80.000 cm

Package 2 Length

120.000 cm

Package 2 Weight

100.000 kg

Warranty

18 months