Trade Price
£92.29
Per
1
Unit
EA
Pack Quantity
1
TeSys D control relay, 5 contacts (5NO), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 125V DC control circuit with no inrush consumption and equipped with a surge suppression device, connection by screw clamp terminals. For high operating rates until 180 cycles/min and ambient temperature -40/+60°C, it procures high reliability and durability. Compact (45mm width), for clipping on 35mm DIN rail or fixing by screw. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium product (RoHS/REACh).
Range
TeSys TeSys Deca
Product name
TeSys CAD
Product or component type
Control relay
Device short name
CAD
contactor application
Control circuit
utilisation category
DC-13 AC-14 AC-15
Pole contact composition
5 NO
[Ue] rated operational voltage
<= 690 V AC 25...400 Hz
Control circuit type
DC standard
[Uc] control circuit voltage
125 V DC
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
[Ith] conventional free air thermal current
10 A (at 60 °C)
Irms rated making capacity
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1
[Icw] rated short-time withstand current
100 A - 1 s 120 A - 500 ms 140 A - 100 ms
Associated fuse rating
10 A gG conforming to IEC 60947-5-1
[Ui] rated insulation voltage
600 V UL certified 600 V CSA certified 690 V conforming to IEC 60947-5-1
mounting support
Plate Rail
Connections - terminals
Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Tightening torque
1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Control circuit voltage limits
0.1...0.25 Uc (-40…70 °C):drop-out DC 0.7...1.25 Uc (-40…60 °C):operational DC 1...1.25 Uc (60…70 °C):operational DC
Operating time
53...72 ms coil energisation and NO closing 16...24 ms coil de-energisation and NO opening
Mechanical durability
30 Mcycles
Maximum operating rate
180 cyc/mn
Time constant
28 ms
Inrush power in W
5.4 W (at 20 °C)
Hold-in power consumption in W
5.4 W at 20 °C
Minimum switching voltage
17 V
Minimum switching current
5 mA
Non-overlap time
1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact
Insulation resistance
> 10 MOhm
Mechanical robustness
Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
height
77 mm
Width
45 mm
Depth
93 mm
Net weight
0.58 kg
Standards
EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1
product certifications
CB Scheme CCC UL CSA EAC CE UKCA
IP degree of protection
IP2X front face conforming to VDE 0106
Protective treatment
TH conforming to IEC 60068
Ambient air temperature for operation
-40…60 °C 60…70 °C with derating
Ambient air temperature for storage
-60…80 °C
Operating altitude
0...3000 m
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
10.500 cm
Package 1 Width
8.600 cm
Package 1 Length
5.000 cm
Package 1 Weight
497.000 g
Unit Type of Package 2
S02
Number of Units in Package 2
15
Package 2 Height
15.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
7.763 kg
Warranty
18 months
Datasheet
Technical Data