Trade Price
£615.25
Per
1
Unit
EA
Pack Quantity
1
TeSys D pre-assembled star-delta starter, for motor control applications up to 18.5kW@400V in delta connection. Plate mounted starter, open version, composed of 3 contactors LC1D with 240V 50/60Hz AC coils, 1NC built-in auxiliary contact on star, a time-delay contact block 1-30 sec. For operating rates until 30 starts/hour, maximum starting time 30 sec. Compact assembly (144mm width), screw fixing. Equipped with pre-wired star delta power connections, and mechanical interlock, the use of a thermal overload relay (to be ordered separately) is strongly recommended. Green Premium compliant (RoHS/REACh).
Range
TeSys TeSys Deca
Product name
TeSys Deca
Product or component type
Star delta starter
Device short name
LC3D
contactor application
Motor control
utilisation category
AC-3
Device presentation
Pre-wired
Poles description
3 x 3P
power pole contact composition
3 x 3 NO
[Ue] rated operational voltage
Power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current
18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
Motor power kW
11 kW at 220/230 V AC 50/60 Hz 22 kW at 415 V AC 50/60 Hz 22 kW at 440 V AC 50/60 Hz 18.5 kW at 380/400 V AC 50/60 Hz
Control circuit type
AC at 50/60 Hz
[Uc] control circuit voltage
240 V AC 50/60 Hz
Auxiliary contact composition
1 NC for KM1 star contactor
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
Overvoltage category
III
[Ui] rated insulation voltage
Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified
Electrical durability
1.65 Mcycles 18 A AC-3 at Ue <= 440 V
safety cover
Protective cover
Interlocking type
Mechanical
mounting support
Plate
standards
EN 60947-4-1 CSA C22.2 No 14 IEC 60947-4-1 UL 508 EN 60947-5-1 IEC 60947-5-1 IEC 60335-1
product certifications
CSA RINA GOST DNV GL LROS (Lloyds register of shipping) CCC BV UL
Connections - terminals
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable end
Tightening torque
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Maximum operating rate
30 cyc/h 60 °C
Starting time
30 s
Coil technology
Without built-in suppressor module
Control circuit voltage limits
Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C) Operational: 0.8...1.1 Uc at 50 Hz (at <60 °C) Operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
Inrush power in VA
70 VA 60 Hz cos phi 0.75 (at 20 °C) 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA
7.5 VA 60 Hz cos phi 0.3 (at 20 °C) 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation
2…3 W at 50/60 Hz
Auxiliary contacts type
Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC Mirror contact conforming to IEC 60947-4-1 3 x 1 NC
Signalling circuit frequency
25...400 Hz
Minimum switching current
5 mA for signalling circuit
minimum switching voltage
17 V for signalling circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Width
144 mm
height
124 mm
Depth
143 mm
Net weight
1.73 kg
Insulation resistance
> 10 MOhm for signalling circuit
IP degree of protection
IP20 front face conforming to IEC 60529
Climatic withstand
conforming to IACS E10 conforming to IEC 60947-1 Annex Q category D
Protective treatment
TH conforming to IEC 60068-2-30
Pollution degree
3
Ambient air temperature for storage
-60…80 °C
Ambient air temperature for operation
-40…70 °C at Uc
Operating altitude
3000 m without derating
Fire resistance
850 °C conforming to IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
17.5 cm
Package 1 Width
15.7 cm
Package 1 Length
23.0 cm
Package 1 Weight
1.721 kg
Unit Type of Package 2
S06
Number of Units in Package 2
27
Package 2 Height
73.5 cm
Package 2 Width
60.0 cm
Package 2 Length
80.0 cm
Package 2 Weight
59.467 kg
Warranty
18 months
Datasheet
Technical Data