Trade Price
£47.98
Per
1
Unit
EA
Pack Quantity
1
Range of product
Harmony K
Product or component type
Complete cam switch
Component name
K1
[Ith] conventional free air thermal current
12 A
Mounting location
Front
Fixing mode
Ø 22 mm hole
Cam switch head type
With front plate 45 x 45 mm
Type of operator
Black handle, length = 35 mm
Rotary handle padlocking
Without
Presentation of legend
With metallic legend, 1 - 2 - 3 - 4 - 5 black marking
Cam switch function
Stepping switch
Return
Without
Off position
Without Off position
Poles description
1P
Switching positions
Right: 0° - 45° - 90° - 135° - 180°
IP degree of protection
IP65 conforming to IEC 60529
Number of steps
5
Switching angle
45 °
[Ui] rated insulation voltage
690 V (pollution degree 3) conforming to IEC 60947-1
[Ithe] conventional enclosed thermal current
10 A
Rated operational power in W
10500 W AC-21, 500...660 V 3 phases conforming to IEC 947-3 1100 W AC-3, 230 V 3 phases conforming to IEC 947-3 1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3 1500 W AC-3, 400 V 1 phase conforming to IEC 947-3 1500 W AC-3, 400 V 3 phases conforming to IEC 947-3 1500 W AC-3, 500 V 3 phases conforming to IEC 947-3 1500 W AC-3, 690 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 400 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 500 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 690 V 3 phases conforming to IEC 947-3 4800 W AC-21, 230 V 3 phases conforming to IEC 947-3 600 W AC-3, 230 V 1 phase conforming to IEC 947-3 8300 W AC-21, 400 V 3 phases conforming to IEC 947-3
[Ie] rated operational current AC
1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3 2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3 2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3 3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3 3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3 4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3 4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3 5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3 1 A at 500 V AC-15 conforming to IEC 947-5-1 2 A at 400 V AC-15 conforming to IEC 947-5-1 3 A at 230 V AC-15 conforming to IEC 947-5-1
Electrical durability
1000000 cycles AC-15 1000000 cycles AC-21 500000 cycles AC-23 500000 cycles AC-3
Maximum operating rate
2.5 cyc/mn AC-21 2.5 cyc/mn AC-23 2.5 cyc/mn AC-3 8.333 cyc/mn AC-15
Short-circuit current
10000 A
Short-circuit protection
16 A cartridge fuse, type gG
[Uimp] rated impulse withstand voltage
4 kV in isolating function 6 kV conforming to IEC 947-1
contact operation
Slow-break
Positive opening
With
Electrical connection
Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm² Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm²
Mechanical durability
1000000 cycles
CAD overall width
45 mm
CAD overall height
50 mm
CAD overall depth
69 mm
Net weight
0.18 kg
Standards
IEC 60947-3 for power circuit IEC 60947-5-1 for control circuit CENELEC EN 50013
Product certifications
CSA 240 V 3 hp 3 phases 2 -pole(s) UL 240 V 0.33 hp 1 phase 2 -pole(s) CSA 240 V 1 hp 1 phase UL 240 V 1 hp 3 phases
Protective treatment
TC
Ambient air temperature for operation
-25…55 °C
Ambient air temperature for storage
-40…70 °C
Shock resistance
30 gn conforming to IEC 68-2-27
Vibration resistance
5 gn conforming to IEC 68-2-6 (f = 10…150 Hz)
Overvoltage category
Class II conforming to IEC 536 Class II conforming to NF C 20-030
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
6.5 cm
Package 1 Width
6.5 cm
Package 1 Length
16.5 cm
Package 1 Weight
200.0 g
Unit Type of Package 2
S01
Number of Units in Package 2
8
Package 2 Height
15.0 cm
Package 2 Width
15.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
1.764 kg
Warranty
18 months
Datasheet
Selection Charts