K1D032B

K1CAM BCD12 F

Trade Price

£28.04

Per

1

Unit

EA

Pack Quantity

1

K1D032B

Technical Specifications

Range of product

Harmony K

Product or component type

Cam switch body

Component name

K1

[Ith] conventional free air thermal current

12 A

Sub-assembly composition

Contact blocks + fixing plate

Cam switch function

BCD encoded output switch

Off position

Without Off position

Switching positions

Right: 0°-30°-60°-90°-120°-150°-180°-210°-240°-270°-300°-330°

Mounting location

Front

Fixing mode

Ø 22 mm hole

bezel material

Plastic

Number of decimal

12

Switching angle

30 °

[Ui] rated insulation voltage

690 V (pollution degree 3) conforming to IEC 60947-1

[Ithe] conventional enclosed thermal current

10 A

Rated operational power in W

10500 W AC-21, 500 - 660 V 3 phases conforming to IEC 947-3 1100 W AC-3, 230 V 3 phases conforming to IEC 947-3 1500 W AC-23A, 230 V 3 phases conforming to IEC 947-3 1500 W AC-3, 400 V 1 phase conforming to IEC 947-3 1500 W AC-3, 400 V 3 phases conforming to IEC 947-3 1500 W AC-3, 500 V 3 phases conforming to IEC 947-3 1500 W AC-3, 690 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 400 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 500 V 3 phases conforming to IEC 947-3 2200 W AC-23A, 690 V 3 phases conforming to IEC 947-3 4800 W AC-21, 230 V 3 phases conforming to IEC 947-3 600 W AC-3, 230 V 1 phase conforming to IEC 947-3 8300 W AC-21, 400 V 3 phases conforming to IEC 947-3

[Ie] rated operational current AC

1.8 A at 690 V AC-3 3 phases conforming to IEC 947-3 2.8 A at 500 V AC-3 3 phases conforming to IEC 947-3 2.8 A at 690 V AC-23A 3 phases conforming to IEC 947-3 3.3 A at 400 V AC-3 3 phases conforming to IEC 947-3 3.8 A at 500 V AC-23A 3 phases conforming to IEC 947-3 4.6 A at 230 V AC-3 3 phases conforming to IEC 947-3 4.8 A at 400 V AC-23A 3 phases conforming to IEC 947-3 5.6 A at 230 V AC-23A 3 phases conforming to IEC 947-3 1 A at 500 V AC-15 conforming to IEC 947-5-1 2 A at 400 V AC-15 conforming to IEC 947-5-1 3 A at 230 V AC-15 conforming to IEC 947-5-1

Electrical durability

1000000 cycles AC-15 1000000 cycles AC-21 500000 cycles AC-23 500000 cycles AC-3

Maximum operating rate

2.5 cyc/mn AC-21 2.5 cyc/mn AC-23 2.5 cyc/mn AC-3 8.333 cyc/mn AC-15

Short-circuit current

10000 A

Short-circuit protection

16 A cartridge fuse, type gG

[Uimp] rated impulse withstand voltage

4 kV in isolating function 6 kV conforming to IEC 947-1

contact operation

Slow-break

Positive opening

With

Electrical connection

Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm² Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm²

Mechanical durability

1000000 cycles

Net weight

0.11 kg

Standards

IEC 60947-3 for power circuit IEC 60947-5-1 for control circuit CENELEC EN 50013

Product certifications

CSA 240 V 1 hp 1 phase CSA 240 V 3 hp 3 phases 2 -pole(s) UL 240 V 1 hp 3 phases UL 240 V 0.33 hp 1 phase 2 -pole(s)

Protective treatment

TC

Ambient air temperature for operation

-25…55 °C

Ambient air temperature for storage

-40…70 °C

Shock resistance

30 gn conforming to IEC 68-2-27

Vibration resistance

5 gn conforming to IEC 68-2-6 (f = 10…150 Hz)

Overvoltage category

Class II conforming to IEC 536 Class II conforming to NF C 20-030

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

6.5 cm

Package 1 Width

6.5 cm

Package 1 Length

8.0 cm

Package 1 Weight

120.0 g

Unit Type of Package 2

S01

Number of Units in Package 2

16

Package 2 Height

15.0 cm

Package 2 Width

15.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

2.101 kg

Warranty

18 months

Document Links