Trade Price
£235.44
Per
1
Unit
EA
Pack Quantity
1
This Harmony RM35-T multi function control relay allows monitoring of power supply circuits in 3-phase networks. This modular multi function 3-phase control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.
Range of produc
Harmony Control Relays
Relay type
Multifunction control relay
Product or component type
3-phase control relay
Product specific application
For 3-phase supply
Relay name
RM35TF
Relay monitored parameters
Undervoltage and overvoltage in window mode Phase sequence Phase failure detection Asymmetry
time delay
Adjustable 0.1...10 s, +/- 10 % of the full scale value
Switching capacity in VA
1250 VA
Measurement range
220...480 V voltage AC
Contacts type and composition
2 C/O
[Uc] control circuit voltage
220...480 V
Reset time
1500 ms at 480 V
Maximum switching voltage
250 V AC 250 V DC
Minimum switching current
10 mA at 5 V DC
Maximum switching current
5 A AC 5 A DC
Supply voltage limits
194…528 V AC, 3 phases
Control circuit voltage limits
- 12 % + 10 % Un
Power consumption in VA
0…22 VA at 400 V AC 50 Hz
Voltage detection threshold
< 194 V
control circuit frequency
50...60 Hz +/- 10 %
Output contacts
2 C/O
Nominal output current
5 A
Measurement voltage limits
176…528 V AC
Hysteresis
2 %
delay at power up
650 ms
Maximum measuring cycle
140 ms measurement cycle as true rms value
Threshold adjustment voltage
-20...-2 % in the range 380...480 V AC 2...20 % of Un selected -12...-2 % in the range 220 V AC +2...+20 % in the range 220...440 V AC +2...+10 % in the range 480 V AC
Voltage range
220...480 V phase to phase
Adjustment of asymmetry threshold
5...15 % of Un selected
Repeat accuracy
0.3 % for time delay 0.5 % for input and measurement circuit
Measurement error
< 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation
Response time
< 200 ms (in the event of a fault)
Marking
CE
Overvoltage category
III conforming to IEC 60664-1
Insulation resistance
> 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1
[Ui] rated insulation voltage
400 V conforming to IEC 60664-1
Supply frequency
50/60 Hz +/- 10 %
Operating position
Any position without derating
Connections - terminals
Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque
0.6…1 N.m conforming to IEC 60947-1
Housing material
Self-extinguishing plastic
Local signalling
LED (green) for power ON LED (yellow) for relay ON LED (yellow) for fault
Mounting support
35 mm symmetrical DIN rail conforming to IEC 60715
Electrical durability
100000 cycles
Mechanical durability
30000000 cycles
Operating rate
<= 360 operations/hour full load
Utilisation category
AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1
Safety reliability data
MTTFd = 399.5 years B10d = 360000
Width
35 mm
Net weight
0.13 kg
Electromagnetic compatibility
Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to IEC 61000-6-2
Standards
IEC 60255-1
product certifications
GL UL CSA GOST C-Tick
Directives
89/336/EEC - electromagnetic compatibility 73/23/EEC - low voltage directive
Ambient air temperature for storage
-40…70 °C
Ambient air temperature for operation
-20…50 °C
Relative humidity
95 % at 55 °C conforming to IEC 60068-2-30
Vibration resistance
0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1
Shock resistance
15 gn for 11 ms conforming to IEC 60255-21-1
IP degree of protection
IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529
Pollution degree
3 conforming to IEC 60664-1
Dielectric test voltage
2 kV, 1 min AC 50 Hz
Non-dissipating shock wave
4 kV
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.800 cm
Package 1 Width
7.800 cm
Package 1 Length
9.700 cm
Package 1 Weight
133.000 g
Unit Type of Package 2
S03
Number of Units in Package 2
48
Package 2 Height
30.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
7.070 kg
Unit Type of Package 3
P06
Number of Units in Package 3
384
Package 3 Height
75.000 cm
Package 3 Width
60.000 cm
Package 3 Length
80.000 cm
Package 3 Weight
64.124 kg
Warranty
18 months
Datasheet
Technical Data