This Altivar 12 variable speed drive can feed 3-phase asynchronous motors in supply line connection. It works at a rated power up to 3kW / 4hp and a rated voltage from 200V to 240V AC. It is designed with heatsink for normal environments and fan-cooled enclosure. Transient overtorque function prevents stoppages by unjamming the machine with extra torque, when needed, this reduces downtime and maintenance costs. It features underload and overload detection, this contribute to protect your installation. The Altivar 12 drive integrates as standard the Modbus communication protocol, which can be accessed via the RJ45 connector located on the underside of the drive. It is designed for simple industry and commercial machines and appliances, such as conveyors, pumps, extractors, access barriers and treadmills. SoMove software compatibility enables saving and transfering of configurations to spare drive, reducing maintenance downtime. It features an optimized application of power and torque for ventilation and pumping applications, this allows up to 30% energy savings.
Range of product
Altivar 12
Product or component type
Variable speed drive
Product specific application
Simple machine
Mounting mode
Cabinet mount
Communication port protocol
Modbus
Supply frequency
50/60 Hz +/- 5 %
[Us] rated supply voltage
200...240 V - 15...10 %
Nominal output current
12.2 A
Motor power hp
4 hp
Motor power kW
3 kW
EMC filter
Without EMC filter
IP degree of protection
IP20
Discrete input number
4
Discrete output number
2
analogue input number
1
analogue output number
1
Relay output number
1
Physical interface
2-wire RS 485
Connector type
1 RJ45
Continuous output current
12.2 A at 4 kHz
Method of access
Server Modbus serial
Speed drive output frequency
0.5…400 Hz
Speed range
1…20
Sampling duration
20 ms, tolerance +/- 1 ms for logic input 10 ms for analogue input
Linearity error
+/- 0.3 % of maximum value for analogue input
Frequency resolution
Analog input: converter A/D, 10 bits Display unit: 0.1 Hz
Time constant
20 ms +/- 1 ms for reference change
Transmission rate
9.6 kbit/s 19.2 kbit/s 38.4 kbit/s
Transmission frame
RTU
Number of addresses
1…247
Data format
8 bits, configurable odd, even or no parity
Communication service
Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43)
Type of polarization
No impedance
4 quadrant operation possible
False
Asynchronous motor control profile
Sensorless flux vector control Quadratic voltage/frequency ratio Voltage/frequency ratio (V/f)
Maximum output frequency
4 kHz
Transient overtorque
150…170 % of nominal motor torque depending on drive rating and type of motor
Acceleration and deceleration ramps
Linear from 0 to 999.9 s S U
Motor slip compensation
Adjustable Preset in factory
Switching frequency
2...16 kHz adjustable 4...16 kHz with derating factor
Nominal switching frequency
4 kHz
Braking to standstill
By DC injection
Brake chopper integrated
False
Line current
19.0 A at 100 V (heavy duty) 15.9 A at 120 V (heavy duty)
Maximum input current
15.9 A
Maximum output voltage
240 V
Apparent power
6.6 kVA at 240 V (heavy duty)
Maximum transient current
18.3 A during 60 s (heavy duty) 20.1 A during 2 s (heavy duty)
Network frequency
50...60 Hz
Relative symmetric network frequency tolerance
5 %
Prospective line Isc
5 kA
Base load current at high overload
12.2 A
Power dissipation in W
Forced cooling: 94.0 W
With safety function Safely Limited Speed (SLS)
False
With safety function Safe brake management (SBC/SBT)
False
With safety function Safe Operating Stop (SOS)
False
With safety function Safe Position (SP)
False
With safety function Safe programmable logic
False
With safety function Safe Speed Monitor (SSM)
False
With safety function Safe Stop 1 (SS1)
False
With sft fct Safe Stop 2 (SS2)
False
With safety function Safe torque off (STO)
False
With safety function Safely Limited Position (SLP)
False
With safety function Safe Direction (SDI)
False
Protection type
Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t
tightening torque
1.2 N.m
insulation
Electrical between power and control
Quantity per set
Set of 1
Width
140 mm
height
184 mm
Depth
141.2 mm
Net weight
2 kg
Operating altitude
<= 1000 m without derating > 1000...3000 m with current derating 1 % per 100 m
Operating position
Vertical +/- 10 degree
product certifications
NOM CSA C-Tick UL GOST RCM KC
Marking
CE
standards
UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3
Assembly style
With heat sink
Electromagnetic compatibility
Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3 Surge immunity test level 3 conforming to EN/IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11
Environmental class (during operation)
Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)
150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)
10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation)
1.5 mm at 2...13 Hz
Volume of cooling air
16.4 m3/h
Overvoltage category
Class III
Regulation loop
Adjustable PID regulator
Electromagnetic emission
Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2...16 kHz shielded motor cable Conducted emissions conforming to EN/IEC 61800-3
Vibration resistance
1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 3…13 Hz) - drive unmounted on symmetrical DIN rail - conforming to EN/IEC 60068-2-6
Shock resistance
15 gn conforming to EN/IEC 60068-2-27 for 11 ms
Relative humidity
5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3
Noise level
50 dB
Pollution degree
2
Ambient air transport temperature
-25…70 °C
Ambient air temperature for operation
-10…50 °C without derating 50…60 °C with current derating 2.2 % per °C
Ambient air temperature for storage
-25…70 °C
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
22.000 cm
Package 1 Width
21.500 cm
Package 1 Length
22.000 cm
Package 1 Weight
2.436 kg
Unit Type of Package 2
P06
Number of Units in Package 2
12
Package 2 Height
75.000 cm
Package 2 Width
60.000 cm
Package 2 Length
80.000 cm
Package 2 Weight
42.232 kg
Warranty
18 months
Datasheet