Technical Specifications

Neutral posi­tion

without neutral

Number of protected poles

1

Number of poles

1 P

Trip Unit

TM F/F

Integ­rated earth fault protec­tion

No

Concur­rently switching N-neutral

No

Motor drive integ­rated

No

Rated oper­a­tional voltage Ue

220 / 240 V

Frequency

50 to 60 Hz

Rated insu­la­tion voltage

690 V

Rated impulse with­stand voltage

8 kV

With under voltage release

No

Rated current

63 A

Thermal protec­tion nob setting xIN

1

Rating current 10°C according to IEC 60947

76.8 A

Rating current 150°C according to IEC 60947

75.2 A

Rating current 20°C according to IEC 60947

73.6 A

Rating current 25°C according to IEC 60947

71.9 A

Rating current 30°C according to IEC 60947

70.2 A

Rating current 35°C according to IEC 60947

68.5 A

Rating current 40°C according to IEC 60947

66.7 A

Rating current 45°C according to IEC 60947

64.8 A

Rating current 50°C according to IEC 60947

63 A

Rating current 55°C according to IEC 60947

61 A

Rating current 60°C according to IEC 60947

59 A

Rating current 65°C according to IEC 60947

56.9 A

Rating current 70°C according to IEC 60947

54.7 A

Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 230V AC IEC 60947-2

35 kA

Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 240V AC IEC 60947-2

35 kA

Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 400V AC IEC 60947-2

25 kA

Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 415V AC IEC 60947-2

25 kA

Range of the thermal adjust­ment

63 A

Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 380V AC IEC 60947-2

25 kA

Depth of installed product

68 mm

Height of installed product

130 mm

Width of installed product

25 mm

Total power loss under IN

5.1 W

Power loss per pole at In

5.1 W

Elec­tric endur­ance in number of cycles

1000

Number of mech­an­ical oper­a­tions

4000

Range of the magnetic adjust­ment

1000 A

Number of auxil­iary contacts as normally closed contact

0

Number of auxil­iary contacts as normally open contact

0

Number of auxil­iary contacts as change-over contact

0

Can be access­or­ized

Yes

Standard text

IEC 60947-2

European directive WEEE

concerned

Degree of pollu­tion according to IEC 60664 / IEC 60947-2

3

Alti­tude

2000 m

Temper­ature of calib­ra­tion

50 °C

Document Links