MCN125

MCB 1P 6kA C-25A 1M

Trade Price

£17.97

Per

1

Unit

EA

Pack Quantity

12

MCN125
MCN125
MCN125

Technical Specifications

Number of protected poles

1

Number of poles

1 P

Type of pole

1 P

Curve

C

Concur­rently switching N-neutral

No

Number of modules

1

Top connec­tion aligne­ment for modular devices

Aligned terminal

Bottom connec­tion aligne­ment for modular devices

Aligned terminal

Rated short circuit breaking capa­city Icn AC according IEC60898-1

6 kA

Rated oper­a­tional voltage Ue

230 / 400 V

Type of supply voltage

AC

Frequency

50 to 60 Hz

Rated insu­la­tion voltage

500 V

Rated impulse with­stand voltage

4000 V

Rated current

25 A

Rated service breaking capa­city Ics AC according IEC 60898-1

6 kA

min/maxi threshold value of the AC thermal oper­a­tion

1.13 / 1.45 In

Magnetic regu­lating currrent

5 / 10 In

min/maxi threshold value of the DC magnetic oper­a­tion

7 / 15 In

min/maxi threshold value of the DC thermal oper­a­tion

1.13 / 1.45 In

Breaking capa­city on 1 pole for IT 400V NF 60947-2

3 kA

Rated short circuit breaking capa­city Icn under 230V AC according IEC60898-1

6 kA

Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 230V AC IEC 60947-2

10 kA

Rated ulti­mate short-­cir­cuit breaking capa­city Icu under 240V AC IEC 60947-2

10 kA

Rating current -25°C

33.4 A

Rating current -20°C

32.6 A

Rating current -15°C

31.8 A

Rating current -10°C

31 A

Rating current -5°C

30.3 A

Rating current 0°C

29.5 A

Rating current 5°C

28.7 A

Rating current 10°C

28 A

Rating current 15°C

27.2 A

Rating current 20°C

26.4 A

Rating current 25°C

25.7 A

Rating current 30°C

25 A

Rating current 35°C

24.1 A

Rating current 40°C

23.4 A

Rating current 45°C

22.6 A

Rating current 50°C

21.8 A

Rating current 55°C

21.1 A

Rating current 60°C

20.3 A

Rating current 65°C

19.5 A

Rating current 70°C

18.8 A

Correc­tion factor of rating current for 2 devices placed side-by-side

1

Correc­tion factor of rating current for 3 devices placed side-by-side

0.95

Correc­tion factor of rating current for 4 and 5 devices placed side-by-side

0.9

Correc­tion factor of rating current for 6 devices placed side-by-side

0.85

Correc­tion factor of magnetic trip­ping with 100 Hz

1.1

Correc­tion factor of magnetic trip­ping with 200 Hz

1.2

Correc­tion factor of magnetic trip­ping with 400 Hz

1.5

Correc­tion factor of magnetic trip­ping with 60 Hz

1

Depth of installed product

70 mm

Height of installed product

83 mm

Width of installed product

17.5 mm

Total power loss under IN

3 W

Power loss per pole at In

3 W

Elec­tric endur­ance in number of cycles

4000

Number of mech­an­ical oper­a­tions

20000

Type of top connec­tion for modular devices

with screw

Tight­ening torque

2,8Nm

Type of Bottom Connec­tion for modular devices

BIcon­nect

Connec­tion cross-sec­tion of input and output with screws, for massive conductors

1 / 35 mm²

Connec­tion cross section of access and exit with screws, for flex­ible conductor

1 / 25 mm²

Type of connec­tion

with screw

Standard text

EN 60898-1

European directive WEEE

concerned

Protec­tion index IP

IP20

Oper­ating temper­ature

-25…70 °C

Degree of pollu­tion according to IEC 60664 / IEC 60947-2

2

Class of energy limit­a­tion I²t

3

Alti­tude

2000 m

Air humidity protec­tion

for all climates

Stor­age/trans­port temper­ature

-25…80 °C

Document Links

Datasheet