Trade Price
£61.64
Per
1
Unit
EACH
Pack Quantity
1
Eaton Moeller® series LSE Safety position switch, LSE, Position switch with electronically adjustable operating point, Basic device, expandable, 2 NC, Yellow, Insulated material, Cage Clamp, -25 - +70 °C
Product Length/Depth
33.5 mm
Product Height
76.5 mm
Product Width
31 mm
Product Weight
0.048 kg
Compliances
CE Marked
Certifications
CSA Std. C22.2 No. 14
EN 60947-5
IEC 60947-5
UL 508
CE
CSA
UL
CSA Class No.: 3211-03
IEC/EN 61000-4
UL Category Control No.: NKCR
CSA-C22.2 No. 14
IEC/EN 60947
IEC/EN 60947-5
CSA File No.: 012528
UL File No.: E29184
Rated operational current for specified heat dissipation (In)
0.2 A
Contact configuration
2 NC
Repetition accuracy
0.02 mm (Contacts/switching capacity)
Terminal capacity (flexible with ferrule)
1 x (0.5 - 1.5) mm²
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Enclosure color
Yellow Cover
Temperature resistance
100 °C, Contact temperature of roller head
Rated operational voltage
12 - 30 V DC
Rated operational current (Ie) at DC-13, 125 V
0 A
Diameter sensor
0 mm
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Surge rating
0.5 kV, Power pulses (Surge), according to IEC/EN 61000-4-5, EMC
Fitted with:
Status indication
Interface type
None
10.8 Connections for external conductors
Is the panel builder's responsibility.
Rated operational current (Ie) at DC-1, 24 V
18 A
Immunity to line-conducted interference
10 V (according to IEC/EN 61000-4-6)
Actuator type
Plunger
Sensor height
61 mm
Explosion safety category for gas
None
Contact discharge
4 kV, according to IEC/EN 61000-4-2, Level 3, ESD
Sensor length
33.5 mm
Enclosure type
Cuboid
Actuating torque of rotary drives
0.2 Nm
Ambient operating temperature - max
70 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Rated operational current (Ie) at AC-15, 24 V
0 A
Features
Expandable
Static heat dissipation, non-current-dependent Pvs
0.4 W
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
Ambient operating temperature - min
-25 °C
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
Rated breaking capacity
0.019 A (30 V DC)
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Mounting position
As required
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
0 A
Electric connection type
Cable entry metrical
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Rated switching distance (Sn) - max
5.5 mm
Number of contacts (normally closed contacts)
2
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Width sensor
31 mm
Heat dissipation per pole, current-dependent Pvid
0.15 W
Operating frequency
3000 Operations/h
Product category
Position switch
Action
2021118113756-Mechanical Limit Switches.xlsm-Data
Operating temperature - min
-25 °C
Indication
Visual status indication
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Suitable for
Safety functions
Air discharge
8 kV, according to IEC/EN 61000-4-2, Level 3, ESD
Rated switching distance (Sn) - min
0.5 mm
Terminal capacity (solid)
1 x (0.5 - 2.5) mm²
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
Operating temperature - max
40 °C
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
Connection type
Cage Clamp
Operating speed
For angle of actuation α = 0°/30°
Max. 1/0.5 m/s (with DIN cam, mechanical actuation)
Rated operational current (Ie) at DC-13, 220 V, 230 V
0 A
Switch function type
Slow-action switch
Electromagnetic fields
10 V/m (according to IEC EN 61000-4-3)
Voltage rating
12-30 Vdc
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Overvoltage category
III
Degree of protection
IP66/IP67
NEMA Other
Switching hysteresis of Sn
0.4 %
Enclosure material finishing
Other
Pollution degree
3
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
Connection
Cage clamp
Actuator alignment
Roller cam straight
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated operational current (Ie) at AC-15, 125 V
0 A
Functions
Output electronic
Material
Plastic housing
Number of safety auxiliary contacts
0
Enclosure material
Plastic
Insulated material
Explosion safety category for dust
None
Burst impulse
2 kV, Signal cable, according to IEC/EN 61000-4-4, Level 3
2 kV, Supply cable, according to IEC/EN 61000-4-4, Level 3
Type
Safety position switch
10.2.2 Corrosion resistance
Meets the product standard's requirements.
Actuating force at beginning/end of stroke
3.5 N/8.0 N
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
Number of contacts (normally open contacts)
0
Number of contacts (change-over contacts)
0
Lifespan
3,000,000 electrical Operations
3,000,000 mechanical Operations
Shock resistance
30 g, Basic unit, Mechanical, Half-Sinusoidal shock 20 ms
Rated operational current (Ie) at DC-1, 12 V
0.015 A
Rated operational current (Ie) at DC-13, 24 V
0.2 A
Datasheet