Eaton Moeller® series LS Angled roller lever
Product Length/Depth
25 mm
Product Height
45 mm
Product Width
35 mm
Product Weight
0.017 kg
Compliances
CE Marked
Certifications
IEC 60947-5
EN 60947-5
UL 508
CSA Std. C22.2 No. 14
CSA File No.: 012528
IEC/EN 60947-5
CSA
UL
CE
CSA-C22.2 No. 14
UL Category Control No.: NKCR
UL File No.: E29184
CSA Class No.: 3211-03
Rated operational current for specified heat dissipation (In)
0 A
Product category
Angled roller lever
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Actuator type
Square roller lever
Ambient operating temperature - max
70 °C
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
Features
The operating head can be rotated 90° to enable adaptation to the specified approach direction
10.10 Temperature rise
Not applicable.
Static heat dissipation, non-current-dependent Pvs
0 W
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
Ambient operating temperature - min
-40 °C
Type
Operating heads
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.2.4 Resistance to ultra-violet (UV) radiation
Please enquire
10.2.7 Inscriptions
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Heat dissipation per pole, current-dependent Pvid
0 W
Datasheet