Trade Price
£25.31
Per
1
Unit
EACH
Pack Quantity
1
Eaton Moeller® series LS Position switch, Rounded plunger, Basic device, expandable, 1 N/O, 1 NC, Cage Clamp, Yellow, Insulated material, -25 - +70 °C
Product Length/Depth
33.5 mm
Product Height
76.5 mm
Product Width
31 mm
Product Weight
0.051 kg
Certifications
CSA-C22.2 No. 14
IEC/EN 60947
UL 508
CSA File No.: 012528
UL Category Control No.: NKCR
CSA Class No.: 3211-03
UL File No.: E29184
CE
UL
CSA
IEC/EN 60947-5
Rated operational current for specified heat dissipation (In)
6 A
Repetition accuracy
0.15 mm (Contacts/switching capacity)
Terminal capacity (flexible with ferrule)
1 x (0.5 - 1.5) mm²
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Enclosure color
Yellow Cover
Temperature resistance
100 °C, Contact temperature of roller head
Rated operational current (Ie) at DC-13, 125 V
0.8 A
Diameter sensor
0 mm
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Interface type
None
10.8 Connections for external conductors
Is the panel builder's responsibility.
Rated conditional short-circuit current (Iq)
1 kA
Actuator type
Plunger
Sensor height
61 mm
Explosion safety category for gas
None
Sensor length
33.5 mm
Enclosure type
Cuboid
Actuating torque of rotary drives
0.2 Nm
Ambient operating temperature - max
70 °C
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Rated operational current (Ie) at AC-15, 24 V
6 A
Features
Expandable
Positive opening
Forced opening
Static heat dissipation, non-current-dependent Pvs
0 W
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
Ambient operating temperature - min
-25 °C
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Mounting position
As required
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
6 A
Electric connection type
Cable entry metrical
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Number of contacts (normally closed contacts)
1
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Width sensor
31 mm
Heat dissipation per pole, current-dependent Pvid
0.17 W
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V
4 A
Operating frequency
6000 Operations/h
Product category
Rounded plunger
Action
2021118113756-Mechanical Limit Switches.xlsm-Data
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Suitable for
Safety functions
Terminal capacity (solid)
1 x (0.5 - 2.5) mm²
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
Connection type
Cage Clamp
Operating speed
Max. 1/0.5 m/s (with DIN cam, mechanical actuation)
For angle of actuation α = 0°/30°
Rated operational current (Ie) at DC-13, 220 V, 230 V
0.3 A
Switch function type
Slow-action switch
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Control circuit reliability
1 failure per 10,000,000 switching operations (Statistically determined, at 24 V DC/5 mA)
1 failure per 5,000,000 switching operations (statistically determined, at 5 V DC/1 mA)
Overvoltage category
III
Degree of protection
IP66/IP67
NEMA Other
Enclosure material finishing
Other
Pollution degree
3
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
Rated impulse withstand voltage (Uimp)
4000 V AC
Actuator alignment
Roller cam straight
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated operational current (Ie) at AC-15, 125 V
6 A
Number of safety auxiliary contacts
1
Enclosure material
Plastic
Insulated material
Explosion safety category for dust
None
Type
Safety position switch
10.2.2 Corrosion resistance
Meets the product standard's requirements.
Actuating force at beginning/end of stroke
1.0 N/8.0 N
Supply frequency
Max. 400 Hz, Contacts
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
Number of contacts (normally open contacts)
1
Short-circuit protection rating
Max. 6 A gG/gL, Fuse, Contacts
Rated operational current (Ie) at DC-13, 110 V
0.6 A
Number of contacts (change-over contacts)
0
Lifespan
8,000,000 mechanical Operations
Shock resistance
25 g, Standard-action contact, Mechanical, Half-sinusoidal shock 20 ms
Rated operational current (Ie) at DC-13, 24 V
3 A
Rated insulation voltage (Ui)
400 V
Datasheet