PFR-003

FI relay 30 mA

Trade Price

£323.43

Per

1

Unit

EACH

Pack Quantity

1

PFR-003

Information

Eaton Moeller series NZM - Molded Case Circuit Breaker. Earth-leakage circuit-breakers 30mA

Technical Specifications

Product Length/Depth

80 mm

Product Height

45 mm

Product Width

95 mm

Product Weight

0.182 kg

Compliances

IEC

RoHS conform

Certifications

IEC 1008

IEC 755

IEC/EN 60947-2

IEC 1009

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Frame

NZM1/2/3/4

45 mm

Power on-delay time - min

20 ms

Rated control supply voltage (Us) at AC, 50 Hz - min

184 V

10.4 Clearances and creepage distances

Meets the product standard's requirements.

Device width

85 mm

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Mounting Method

Snap fixing, top-hat rail DIN 46277, IEC/EN 60715

Terminals (top and bottom)

Box terminals

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

Rated fault current - max

0.03 A

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

Rated control supply voltage (Us) at DC - min

0 V

Delay time

0.02 ms (non-delayed)

Power consumption

3 W

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

Current rating of relay contact

6 A

Rated control supply voltage (Us) at AC, 50 Hz - max

276 V

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

Terminal protection

Finger/back-of-hand proof to BGV A2, VDE 106 part 100

Special features

Pulse-current sensitive

Integrated auxiliary contact (1 C/O)

Ring-type transformer must also be ordered

not UL/CSA approved

Sensitivity type

Pulse current sensitive, type A

Ambient operating temperature - max

50 °C

Rated control supply voltage (Us) at AC, 60 Hz - min

184 V

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

Terminal capacity (solid/flexible conductor)

0.75 mm² - 1.5 mm² (2x) with ferrules

0.75 mm² - 2.5 mm² (2x) solid, 0.75 mm² - 1.5 mm² (2x) flexible/with ferrules

Power on-delay time - max

20 ms

Features

1 integrated changeover contact (relay contact)

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

Rated control supply voltage (Us) at DC - max

0 V

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

Ambient operating temperature - min

-10 °C

Type

Accessory

Residual current relays

Voltage release

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Rated control supply voltage (Us) at AC, 60 Hz - max

276 V

Rated operating voltage (Ue) - max

276 V

Voltage rating of relay contact

250 V AC / 100 V DC

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

Rated fault current - min

0.03 A

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Document Links

Datasheet