Trade Price
£107.06
Per
1
Unit
EACH
Pack Quantity
1
Eaton Moeller series NZM - Molded Case Circuit Breaker. Module plate 1-hole 3p, size 4
Product Length/Depth
61 mm
Product Height
10 mm
Product Width
135 mm
Product Weight
0.621 kg
Compliances
IEC
UL/CSA
RoHS conform
Certifications
IEC60947
CSA (File No. 22086)
UL (Category Control Number DIHS)
CE marking
CSA certified
UL489
CSA (Class No. 1432-01)
CSA-C22.2 No. 5-09
UL (File No. E31593)
UL listed
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Frame
NZM4
10.4 Clearances and creepage distances
Meets the product standard's requirements.
Suitable for
Three-pole
Copper cable lugs
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Amperage Rating
≦ 1250 A
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
Terminal capacity (copper strip)
10 segments of 40 mm x 1 mm (2x)
10 segments of 50 mm x 1 mm (2x)
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Terminal capacity (flexible cable)
95 mm² - 300 mm² (2x)
250 - 600 AWG/kcmil (1x)
120 mm² - 300 mm² (1x)
Max. 600 AWG/kcmil (2x)
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
Terminal capacity (copper busbar)
50 mm x 10 mm (2x)
40 mm x 10 mm (2x)
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Special features
One hole
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
Number of poles
Three-pole
Type
Accessory
Module plate
Terminal
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Used with
NZM4, N(S)4
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Datasheet