NZM4-XKA

Terminal kit 3P tunnel Type for LZM4 / PN4 / NZM4

Trade Price

£293.45

Per

1

Unit

EACH

Pack Quantity

1

NZM4-XKA

Information

Eaton Moeller series NZM - Molded Case Circuit Breaker. Tunnel terminal, 3p, 1 switch side, size 4

Technical Specifications

Product Length/Depth

88 mm

Product Height

90 mm

Product Width

159 mm

Product Weight

2.529 kg

Compliances

UL/CSA

IEC

RoHS conform

Certifications

CSA (Class No. 1432-01)

CE marking

UL listed

UL (Category Control Number DIHS)

UL (File No. E31593)

CSA certified

UL489

IEC60947

CSA (File No. 22086)

CSA-C22.2 No. 5-09

Terminal capacity (stranded cable)

50 mm² - 240 mm² (4x)

Max. 500 AWG/kcmil (4x)

Max. 500 AWG/kcmil (1x)

50 mm² - 240 mm² (1x)

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Frame

NZM4

10.4 Clearances and creepage distances

Meets the product standard's requirements.

Suitable for

Three-pole

Copper cable

Aluminum cable

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Amperage Rating

≦ 1400 A

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

Number of poles

Three-pole

Type

Accessory

Tunnel terminal

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Used with

NZM4, N(S)4

Model

Other

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Document Links

Datasheet