ZEB32-45/KK

Electronic separate overload 9-45A, Clas

Trade Price

£163.95

Per

1

Unit

EACH

Pack Quantity

1

ZEB32-45/KK
ZEB32-45/KK
ZEB32-45/KK
ZEB32-45/KK

Information

Eaton Moeller® series ZEB Overload relay, Separate mounting, Earth-fault protection: none, Ir= 9 - 45 A, 1 N/O, 1 N/C

Technical Specifications

Product Length/Depth

108 mm

Product Height

110 mm

Product Width

45 mm

Product Weight

0.39 kg

Certifications

CSA-C22.2 No. 14

IEC/EN 60947-4-1

CSA Class No.: 3211-03

UL

CSA

CSA File No.: 2290956

IEC/EN 60947

UL 508

UL File No.: E1230

UL Category Control No.: NKCR

VDE 0660

CE

Catalog Notes

Rated operational current: Switch-on and switch-off conditions based on DC-13, time constant as specified.

Earth fault protection

None

Features

Phase-failure sensitivity (according to IEC/EN 60947, VDE 0660 Part 102)

Functions

Filament bulb (24 V)

Class

Adjustable

Degree of protection

IP20

Mounting method

Separate positioning

Separate mounting

Overload release current setting - min

9 A

Overload release current setting - max

45 A

Overvoltage category

III

Pollution degree

3

Product Category

Electronic overload relays ZEB

Protection

Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)

Rated impulse withstand voltage (Uimp)

6000 V (auxiliary circuits)

6000 V AC

Shock resistance

15 g, Mechanical, According to IEC/EN 60068-2-27, Shock duration 10 ms

Mechanical, According to IEC/EN 60068-2-27

Suitable for

Branch circuits, (UL/CSA)

Voltage type

Self powered

Ambient operating temperature - min

-25 °C

Ambient operating temperature - max

65 °C

Ambient operating temperature (enclosed) - max

65 °C

Climatic proofing

Damp heat, constant, to IEC 60068-2-78

Damp heat, cyclic, to IEC 60068-2-30

Terminal capacity (flexible with ferrule)

2 x (0.75 - 2.5) mm², Control circuit cables

Terminal capacity (solid)

1 x (1.5 - 16) mm², Main cables

2 x (0.75 - 4) mm², Control circuit cables

Terminal capacity (solid/stranded AWG)

2 x (18 - 12), Control circuit cables

1 x (14 - 4), Main cables

Stripping length (main cable)

13 mm

Stripping length (control circuit cable)

8 mm

Screw size

M3.5, Terminal screw, Control circuit cables

Screwdriver size

1 x 6 mm, Terminal screw, Standard screwdriver

2, Terminal screw, Pozidriv screwdriver

Tightening torque

7 lb-in, Screw terminals

0.8 - 1.2 Nm, Screw terminals, Control circuit cables

Conventional thermal current ith of auxiliary contacts (1-pole, open)

5 A

Rated control supply voltage (Us) at AC, 50 Hz - min

0 V

Rated control supply voltage (Us) at AC, 50 Hz - max

0 V

Rated control supply voltage (Us) at AC, 60 Hz - min

0 V

Rated control supply voltage (Us) at AC, 60 Hz - max

0 V

Rated control supply voltage (Us) at DC - min

0 V

Rated control supply voltage (Us) at DC - max

0 V

Rated frequency - min

50 Hz

Rated frequency - max

60 Hz

Rated operational current (Ie) at AC-15, 120 V

1.5 A

Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V

1.5 A

Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V

0.9 A

Rated operational current (Ie) at DC-13, 110 V

0.4 A

Rated operational current (Ie) at DC-13, 220 V, 230 V

0.2 A

Rated operational current (Ie) at DC-13, 24 V

0.9 A

Rated operational current (Ie) at DC-13, 60 V

0.75 A

Rated operational voltage (Ue) at AC - max

690 V

Short-circuit protection rating

Max. 6 A gG/gL, fuse, Without welding, Auxiliary and control circuits

Short-circuit current rating (high fault at 600 V)

100 kA, Fuse, SCCR (UL/CSA)

60 A, Class J, max. Fuse, SCCR (UL/CSA)

Switching capacity (auxiliary contacts, pilot duty)

B600, AC operated (UL/CSA)

R300, DC operated (UL/CSA)

Voltage rating - max

600 V

Number of auxiliary contacts (change-over contacts)

0

Number of auxiliary contacts (normally closed contacts)

1

Number of auxiliary contacts (normally open contacts)

1

Number of contacts (normally closed contacts)

1

Number of contacts (normally open contacts)

1

Equipment heat dissipation, current-dependent Pvid

4.3 W

Heat dissipation capacity Pdiss

0 W

Heat dissipation per pole, current-dependent Pvid

1.43 W

Rated operational current for specified heat dissipation (In)

45 A

Static heat dissipation, non-current-dependent Pvs

0 W

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

10.4 Clearances and creepage distances

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Electrical connection type of main circuit

Screw connection

Adjustable current range - min

9 A

Adjustable current range - max

45 A

Reset function

Automatic

Push-button

Document Links

Datasheet