EMT6

Thermistor relay, hand reset

Trade Price

£127.09

Per

1

Unit

EACH

Pack Quantity

1

EMT6
EMT6
EMT6

Information

Eaton Moeller® series EMT6 Thermistor overload relay for machine protection, 1W , 24-240V50/60Hz, 24-240VDC, without reclosing lockout

Technical Specifications

Product Length/Depth

103 mm

Product Height

83 mm

Product Width

23 mm

Product Weight

0.128 kg

Certifications

CSA Class No.: 3211-03

IEC/EN 60947-8

UL Category Control No.: NKCR

CSA

CSA-C22.2 No. 14

EN 55011

IEC/EN 60947

IEC/EN 61000-4-2

VDE 0660

CSA File No.: 12528

UL

UL 508

UL File No.: E29184

IEC/EN 61000-4-3

CE

Electric connection type

Screw connection

Functions

Test function via separate button

Notifications of mains and faults via LED display

Temperature measuring range - min

0 °C

Temperature measuring range - max

0 °C

Degree of protection

IP20

Mounting position

As required

Overvoltage category

III

Pollution degree

3

Product category

EMT6 thermistor overload relay for machine protection

Protection

Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)

Rated impulse withstand voltage (Uimp)

6000 V AC

4000 V AC

Safe isolation

250 V AC, Between the contacts, According to EN 61140

250 V AC, Between the contacts and power supply, According to EN 61140

Shock resistance

10 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms

Voltage type

AC/DC

Ambient operating temperature - min

-25 °C

Ambient operating temperature - max

60 °C

Ambient operating temperature (enclosed) - min

25 °C

Ambient operating temperature (enclosed) - max

45 °C

Ambient storage temperature - min

45 °C

Ambient storage temperature - max

85 °C

Climatic proofing

Damp heat, cyclic, to IEC 60068-2-30

Damp heat, constant, to IEC 60068-2-78

Air discharge

8 kV

Burst impulse

According to IEC/EN 61000-4-4

1 kV, Signal cable

2 kV, Supply cable

Contact discharge

6 kV

Electromagnetic fields

10 V/m at 80 - 1000 MHz (according to IEC EN 61000-4-3)

3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)

1 V/m at 2.0 - 2.7 GHz (according to IEC EN 61000-4-3)

Immunity to line-conducted interference

10 V (according to IEC/EN 61000-4-6)

Radio interference class

Class B (EN 55011)

Surge rating

According to IEC/EN 61000-4-5, power pulses (Surge), EMC

2 kV, symmetrical, power pulses (Surge), EMC

4 kV, asymmetrical, power pulses (Surge), EMC

Terminal capacity

2 x (0.5 - 1.5) mm², solid

1 x (0.5 - 2.5) mm², solid

1 x (0.5 - 2.5) mm², flexible with ferrule

2 x (0.5 - 1.5) mm², flexible with ferrule

20 - 14 AWG, solid or stranded

Screw size

M3.5, Terminal screw

Screwdriver size

1 x 6 mm, Terminal screw, Standard screwdriver

2, Terminal screw, Pozidriv screwdriver

Tightening torque

1.2 Nm, Screw terminals

Conventional thermal current ith of auxiliary contacts (1-pole, open)

6 A

Pick-up voltage

0.85 - 1.1 V x Uₑ

Power consumption

2 W at DC

3.5 VA at AC

Rated control supply voltage (Us) at AC, 50 Hz - min

24 V

Rated control supply voltage (Us) at AC, 50 Hz - max

240 V

Rated control supply voltage (Us) at AC, 60 Hz - min

24 V

Rated control supply voltage (Us) at AC, 60 Hz - max

240 V

Rated control supply voltage (Us) at DC - min

24 V

Rated control supply voltage (Us) at DC - max

240 V

Rated insulation voltage (Ui)

400 V

Rated operational current (Ie)

1 A at AC-15, 380 V 400 V 415 V (NC)

3 A at AC-14, 380 V 400 V 415 V (NO)

3 A at AC-15, 220 V 230 V 240 V (NO)

3 A at AC-15, 220 V 230 V 240 V

3 A at AC-14, 300 V (NO)

1 A at AC-15, 380 V 400 V 415 V (NO)

3 A at AC-14, 300 V (NC)

3 A at AC-14, 400 V (NC)

3 A at AC-14, 380 V 400 V 415 V (NC)

1 A at AC-15, 300 V (NO)

3 A at AC-15, 220 V 230 V 240 V (NC)

1 A at AC-15, 300 V (NC)

Rated operational voltage (Ue) - max

240 V

Reset resistance

1600 Ω

Short-circuit protection rating

Max. 6 A gG/gL, Fuse, Contacts

Trip resistance

3600 Ω

Voltage rating - max

600 V

Number of contacts (change-over contacts)

0

Number of contacts (normally closed contacts)

1

Number of contacts (normally open contacts)

1

Equipment heat dissipation, current-dependent Pvid

0 W

Heat dissipation capacity Pdiss

0 W

Heat dissipation per pole, current-dependent Pvid

0 W

Rated operational current for specified heat dissipation (In)

0 A

Static heat dissipation, non-current-dependent Pvs

0.8 W

Document Links

Datasheet