B3.0/2-PKZ0

3-phase common link PKZM0..w/o aux.cont.

Trade Price

£13.93

Per

1

Unit

EACH

Pack Quantity

1

B3.0/2-PKZ0
B3.0/2-PKZ0
B3.0/2-PKZ0
B3.0/2-PKZ0

Information

Eaton Moeller® series B3 Three-phase busbar link, Circuit-breaker: 2, 90 mm, For PKZM0-... or PKE12, PKE32 without side mounted auxiliary contacts or voltage releases

Technical Specifications

Product Length/Depth

90 mm

Product Height

34 mm

Product Width

11 mm

Product Weight

0.035 kg

Certifications

CSA-C22.2 No. 14

UL File No.: E36332

CSA File No.: 98494

UL Category Control No.: NLRV

CE

IEC/EN 60947-4-1

CSA

UL 508

CSA Class No.: 3211-06

UL

Catalog Notes

For parallel power feed to several motor-protective circuit-breakers on terminals 1, 3, 5

Color

Black

Electric connection type

Fork

Features

Insulated

Functions

Can be extended by rotating installation

Number of phases

3

Number of poles

Three-pole

Mounting width

45 mm

Overvoltage category

III

Pollution degree

3

Product category

Accessories

Rated impulse withstand voltage (Uimp)

6000 V AC

Suitable for

2 Circuit-breakers

Used with

PKZ0

PKE12

PKE32

Ambient operating temperature - min

-25 °C

Ambient operating temperature - max

55 °C

Rated operational voltage (Ue) - max

690 V

Rated operational voltage (Ue) at AC - max

690 V

Rated uninterrupted current (Iu)

63 A

Rated conditional short-circuit current (Iq)

0 kA

Rated short-time withstand current (Icw)

0 kA

Equipment heat dissipation, current-dependent Pvid

3 W

Heat dissipation capacity Pdiss

0 W

Heat dissipation per pole, current-dependent Pvid

1 W

Rated operational current for specified heat dissipation (In)

63 A

Static heat dissipation, non-current-dependent Pvs

0 W

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

10.4 Clearances and creepage distances

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Document Links

Datasheet