FAZ-B4/1-HS

MCB, 4A, B-type, SP, 15kA

Trade Price

£46.45

Per

1

Unit

EACH

Pack Quantity

1

FAZ-B4/1-HS

Information

Eaton Moeller series xEffect - FAZ-HS MCB. FAZ-HS, 1-pole, tripping characteristic: B, rated current In: 4 A

Technical Specifications

Product Length/Depth

80 mm

Product Height

75.5 mm

Product Width

17.7 mm

Product Weight

0.112 kg

Compliances

RoHS conform

Certifications

CE marking

IEC/EN 60898

IEC/EN 60947-2

Application

Branch circuits, not as BCPD

Switchgear for industrial and advanced commercial applications

xEffect - Switchgear for industrial and advanced commercial applications

Number of poles

Single-pole

Number of poles (total)

1

Number of poles (protected)

1

Tripping characteristic

B

Release characteristic

B

Amperage Rating

4 A

Type

FAZ-HS

Miniature circuit breaker

Voltage type

AC

Voltage rating

240 V AC / 415 V AC

Voltage rating at DC

60 V DC (per pole)

Voltage rating (UL CSA 13)

277 V AC; 48 V DC

Rated operational voltage (Ue) - max

230 V

Rated insulation voltage (Ui)

440 V

Rated impulse withstand voltage (Uimp)

4 kV

Frequency rating - min

50 Hz

Frequency rating - max

60 Hz

Rated switching capacity (IEC/EN 60947-2)

10 kA

Operational switching capacity

7.5 kA

Rated short-circuit breaking capacity (EN 60898) at 230 V

10 kA

Rated short-circuit breaking capacity (EN 60898) at 400 V

10 kA

Rated short-circuit breaking capacity (IEC 60947-2) at 230 V

15 kA

Rated short-circuit breaking capacity (IEC 60947-2) at 400 V

15 kA

Admissible back-up fuse - max

125 A gL/gG

Selectivity class

3

Overvoltage category

III

Pollution degree

2

Lifespan, electrical

10000 operations

Direction of incoming supply

As required

Frame

45 mm

Enclosure width

80 mm

Width in number of modular spacings

1

Built-in depth

70.5 mm

Mounting width per pole

17.5 mm

Mounting width

17.5 mm

Mounting Method

Top-hat rail IEC/EN 60715

Mounting position

As required

Degree of protection

IP40 (when fitted)

IP20 (IEC)

UL/CSA Type: -

IP20

Terminals (top and bottom)

Twin-purpose terminals

Connectable conductor cross section (solid-core) - min

1 mm²

Connectable conductor cross section (solid-core) - max

25 mm²

Connectable conductor cross section (multi-wired) - min

1 mm²

Connectable conductor cross section (multi-wired) - max

25 mm²

Terminal capacity of screw terminals for main cable

10 mm² (2x)

Terminal capacity (control cable)

25 mm² (1x)

Terminal protection

Finger and hand touch safe, DGUV VS3, EN 50274

Busbar material thickness

0.8 mm - 2 mm

Ambient operating temperature - min

-25 °C

Ambient operating temperature - max

75 °C

Current limiting class

3

Features

Additional equipment possible

Used with

Miniature circuit breaker

FAZ-HS

Document Links

Datasheet