DILM300A/22(RA250)

Contactor, comfort 3pole +2M2B, 160kW

Trade Price

£1,526.00

Per

1

Unit

EACH

Pack Quantity

1

DILM300A/22(RA250)
DILM300A/22(RA250)
DILM300A/22(RA250)
DILM300A/22(RA250)

Information

Eaton Moeller® series DILM Contactor, 380 V 400 V 160 kW, 2 N/O, 2 NC, RA 250: 110 - 250 V 40 - 60 Hz/110 - 350 V DC, AC and DC operation, Screw connection

Technical Specifications

Product Length/Depth

208 mm

Product Height

189 mm

Product Width

140 mm

Product Weight

7.1 kg

Certifications

VDE 0660

UL File No.: E29096

UL Category Control No.: NLDX

UL 60947-4-1

IEC/EN 60947-4-1

CSA Class No.: 3211-04

UL/CSA

CSA File No. 1017510

North America (UL listed, CSA certified)

EN 45545: Fire protection on railway vehicles

IEC 61373: Vibration and shock, tested for category 1 class B

CE marking

Catalog Notes

Contacts according to EN 50012

EN 45545 - Fire protection on railway vehicles: Fire protection class of all plastics according to UL94: V-0 / plastic weight in total: 1.872 kg

Accessories

Fitting options auxiliary contacts: on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA

Application

Contactors for Motors

Connection

Screw terminals

Degree of protection

IP00

Electromagnetic compatibility

Designed for operation in industrial environments. Its use in residential environments may cause radio-frequency interference, requiring additional noise suppression.

Fitted with:

Suppressor circuit in actuating electronics

Lifespan, electrical

100,000 Operations (at Condensor operation)

Lifespan, mechanical

10,000,000 Operations (DC operated)

10,000,000 Operations (AC operated)

Operating frequency

3000 mechanical Operations/h (DC operated)

200 Operations/h

3000 mechanical Operations/h (AC operated)

Overvoltage category

III

Pollution degree

3

Product category

Contactors

Protection

Finger and back-of-hand proof with terminal shroud or terminal block, Protection against direct contact when actuated from front (EN 50274)

Rated impulse withstand voltage (Uimp)

8000 V AC

Resistance

500 mΩ (Admissible transitional contact resistance - of the external control circuit device when actuating A11)

Shock resistance

10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms

10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms

8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms

Signal level

5 V - 15 V, PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2), Magnet systems

Utilization category

AC-1: Non-inductive or slightly inductive loads, resistance furnaces

AC-3: Normal AC induction motors: starting, switch off during running

AC-4: Normal AC induction motors: starting, plugging, reversing, inching

Ambient operating temperature - min

-40 °C

Ambient operating temperature - max

60 °C

Ambient operating temperature (enclosed) - min

40 °C

Ambient operating temperature (enclosed) - max

40 °C

Ambient storage temperature - min

40 °C

Ambient storage temperature - max

80 °C

Climatic proofing

Damp heat, cyclic, to IEC 60068-2-30

Damp heat, constant, to IEC 60068-2-78

Terminal capacity (busbar)

25 mm width, Main connection

Terminal capacity (copper band)

Fixing with flat cable terminal or cable terminal blocks; See terminal capacity for cable terminal blocks

Terminal capacity (flexible with cable lug)

50 - 240 mm²

Terminal capacity (flexible with ferrule)

2 x (0.75 - 2.5) mm², Control circuit cables

1 x (0.75 - 2.5) mm², Control circuit cables

Terminal capacity (solid)

2 x (0.75 - 2.5) mm², Control circuit cables

1 x (0.75 - 2.5) mm², Control circuit cables

Terminal capacity (solid/stranded AWG)

2/0 - 500 MCM, Main cables

18 - 14, Control circuit cables

Terminal capacity (stranded with cable lug)

70 - 240 mm²

Width across flats

16 mm

Screw size

M3.5, Terminal screw, Control circuit cables

M10, Terminal screw, Main connections

Screwdriver size

2, Terminal screw, Control circuit cables, Pozidriv screwdriver

Tightening torque

24 Nm, Main cable connection screw/bolt

1.2 Nm, Screw terminals, Control circuit cables

Inrush current

Max. 30 x Ie (peak)

Rated breaking capacity at 220/230 V

3000 A

Rated breaking capacity at 380/400 V

3000 A

Rated breaking capacity at 500 V

3000 A

Rated breaking capacity at 660/690 V

3000 A

Rated breaking capacity at 1000 V

950 A

Rated insulation voltage (Ui)

1000 V

Rated making capacity (cos phi to IEC/EN 60947)

3600 A

Rated operational current (Ie)

177 A at 690 V (Individual compensation, three-phase capacitors, open)

307 A at up to 525 V (Individual compensation, three-phase capacitors, open)

Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V

490 A

Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V

300 A

Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V

300 A

Rated operational current (Ie) at AC-3, 440 V

300 A

Rated operational current (Ie) at AC-3, 500 V

300 A

Rated operational current (Ie) at AC-3, 660 V, 690 V

185 A

Rated operational current (Ie) at AC-3, 1000 V

95 A

Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V

240 A

Rated operational current (Ie) at AC-4, 440 V

240 A

Rated operational current (Ie) at AC-4, 500 V

240 A

Rated operational current (Ie) at AC-4, 660 V, 690 V

150 A

Rated operational current (Ie) at AC-4, 1000 V

76 A

Rated operational power at AC-3, 240 V, 50 Hz

100 kW

Rated operational power at AC-3, 380/400 V, 50 Hz

160 kW

Rated operational power at AC-3, 415 V, 50 Hz

175 kW

Rated operational power at AC-3, 1000 V, 50 Hz

132 kW

Rated operational power at AC-4, 220/230 V, 50 Hz

75 kW

Rated operational power at AC-4, 240 V, 50 Hz

82 kW

Rated operational power at AC-4, 415 V, 50 Hz

142 kW

Rated operational power at AC-4, 440 V, 50 Hz

150 kW

Rated operational power at AC-4, 500 V, 50 Hz

170 kW

Rated operational power at AC-4, 660/690 V, 50 Hz

137 kW

Rated operational voltage (Ue) at AC - max

1000 V

Rated operational power at AC-4, 1000 V, 50 Hz

108 kW

Safe isolation

1000 V AC, Between coil and contacts, According to EN 61140

Special purpose rating of definite purpose rating

2160 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)

1800 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)

300 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)

360 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)

Short-circuit current rating (basic rating)

700 A, max. Fuse, SCCR (UL/CSA)

600 A, max. CB, SCCR (UL/CSA)

18 kA, SCCR (UL/CSA)

Short-circuit current rating (high fault at 480 V)

250 A, max. CB, SCCR (UL/CSA)

18 kA, Fuse, SCCR (UL/CSA)

700 A, Class L, max. Fuse, SCCR (UL/CSA)

65 kA, CB, SCCR (UL/CSA)

Short-circuit current rating (high fault at 600 V)

700 A, Class J, max. Fuse, SCCR (UL/CSA)

18 kA, CB, SCCR (UL/CSA)

18 kA, Fuse, SCCR (UL/CSA)

600 A, max. CB, SCCR (UL/CSA)

Short-circuit protection rating (type 1 coordination) at 1000 V

200 A gG/gL

Short-circuit protection rating (type 1 coordination) at 400 V

500 A gG/gL

Short-circuit protection rating (type 1 coordination) at 690 V

400 A gG/gL

Short-circuit protection rating (type 2 coordination) at 1000 V

160 A gG/gL

Short-circuit protection rating (type 2 coordination) at 400 V

400 A gG/gL

Short-circuit protection rating (type 2 coordination) at 690 V

315 A gG/gL

Conventional thermal current ith (1-pole, enclosed)

788 A

Conventional thermal current ith (3-pole, enclosed)

315 A

Conventional thermal current ith at 55°C (3-pole, open)

418 A

Conventional thermal current ith of main contacts (1-pole, open)

1000 A

Switching capacity (main contacts, general use)

350 A, Maximum motor rating (UL/CSA)

Switching capacity (auxiliary contacts, general use)

15 A, 600 V AC, (UL/CSA)

1 A, 250 V DC, (UL/CSA)

Switching capacity (auxiliary contacts, pilot duty)

A600, AC operated (UL/CSA)

P300, DC operated (UL/CSA)

Behavior in marginal and transitional conditions

Sealing - Pick-up phase (0.7 x Uc min - 1.15 x Uc max): Contactor switches on with certainty

Sealing - Voltage drops (0.2 - 0.6 x Uc min) > 12 ms: Drop-out of the contactor

Sealing - Voltage drops (0.6 - 0.7 x Uc min: Contactor remains switched on

Sealing - Voltage interruptions 0 - 0.2 x Uc min) > 10 ms: Drop-out of the contactor

Sealing - Excess voltage (1.15 - 1.3 x Uc max): Contactor remains switched on

Sealing - Pick-up phase (0 - 0.7 x Uc min: Contactor does not switch on

Sealing - Voltage drops (0.2 - 0.6 x Uc min <=12 ms: Time is bridged successfully

Sealing - Voltage interruptions (0 - 0.2 x Uc min <= 10 ms: Time is bridged successfully

Drop-out voltage

AC operated: 0.2 x US max - 0.6 x US min, AC operated

0.2 x US max - 0.6 x US min, DC operated

Duty factor

100 %

Pick-up voltage

0.7 - 1.15 V AC x Us

0.7 - 1.15 V DC x Us

Power consumption

110 kW

Control transformer with uk <= 6%

Power consumption, pick-up, 50 Hz

250 W, Pull-in power, Coil in a cold state and 1.0 x Us

380 VA, Pull-in power, Coil in a cold state and 1.0 x Us

Power consumption, pick-up, 60 Hz

250 W, Pull-in power, Coil in a cold state and 1.0 x Us

380 VA, Pull-in power, Coil in a cold state and 1.0 x Us

Power consumption, sealing, 50 Hz

5.5 W, Coil in a cold state and 1.0 x Us

10.5 VA, Coil in a cold state and 1.0 x Us

Power consumption, sealing, 60 Hz

10.5 VA, Coil in a cold state and 1.0 x Us

5.5 W, Coil in a cold state and 1.0 x Us

Rated control supply voltage (Us) at AC, 50 Hz - min

110 V

Rated control supply voltage (Us) at AC, 50 Hz - max

250 V

Rated control supply voltage (Us) at AC, 60 Hz - min

110 V

Rated control supply voltage (Us) at AC, 60 Hz - max

250 V

Rated control supply voltage (Us) at DC - min

110 V

Rated control supply voltage (Us) at DC - max

250 V

Switching time (AC operated, make contacts, closing delay) - max

100 ms

Switching time (AC operated, make contacts, opening delay) - max

110 ms

Assigned motor power at 200/208 V, 60 Hz, 3-phase

100 HP

Assigned motor power at 230/240 V, 60 Hz, 3-phase

125 HP

Assigned motor power at 460/480 V, 60 Hz, 3-phase

250 HP

Assigned motor power at 575/600 V, 60 Hz, 3-phase

300 HP

Number of auxiliary contacts (normally closed contacts)

2

Number of auxiliary contacts (normally open contacts)

2

Number of contacts (normally closed contacts)

2

Number of contacts (normally open contacts)

2

Equipment heat dissipation, current-dependent Pvid

21 W

Heat dissipation capacity Pdiss

0 W

Heat dissipation per pole, current-dependent Pvid

7 W

Rated operational current for specified heat dissipation (In)

300 A

Static heat dissipation, non-current-dependent Pvs

5.5 W

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

10.4 Clearances and creepage distances

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Document Links

Datasheet