Q25S1R

KEY-OPERATED BUTTON

Trade Price

£32.41

Per

1

Unit

EACH

Pack Quantity

1

Q25S1R

Information

Eaton Moeller® series RMQ16 Key-operated actuator, 2 positions, maintained Q25S1R

Technical Specifications

Product Length/Depth

50 mm

Product Height

25 mm

Product Width

25 mm

Product Weight

0.023 kg

Certifications

CSA File No.: 46552

UL 508

UL File No.: E29184

CSA Class No.: 3211-03

IEC/EN 60947

CSA-C22.2 No. 14-05

UL

CE

UL Category Control No.: NKCR

CSA

IEC/EN 60947-5

Bezel color

Black

Bezel material

Plastic

Design

Key operated

Fitted with:

Front ring

Accessories

1 key included with supplied equipment.

Degree of protection

NEMA 1

Degree of protection (front side)

IP65

Lifespan, mechanical

3,000,000 Operations

Opening diameter

16 mm

Operating frequency

1800 Operations/h

Operating torque

0.4 Nm

Overvoltage category

III

Pollution degree

3

Product category

RMQ16

Rated impulse withstand voltage (Uimp)

800 V AC

Size

Front dimensions: 25 × 25 mm

Switching angle

45 °

Terminal capacity

0.5 - 1.0 mm²

Terminal size

2.8 x 0.8 mm to DIN 46244, Blade terminal

2.8 x 0.8 mm to DIN 46247 and IEC 60760, Fast-on connectors

Type

Key-operated button

Mounting position

As required

Shock resistance

40 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms

Mechanical, According to IEC/EN 60068-2-27

Ambient operating temperature - min

-25 °C

Ambient operating temperature - max

60 °C

Ambient operating temperature (enclosed) - min

25 °C

Ambient operating temperature (enclosed) - max

40 °C

Climatic proofing

Damp heat, cyclic, to IEC 60068-2-30

Damp heat, constant, to IEC 60068-2-78

Rated insulation voltage (Ui)

250 V

Rated operational voltage (Ue) at AC - max

24 V

Actuator color

Black

Actuator function

Maintained

Key withdrawable in position 0

Switching function latching

Actuator type

Key

Number of switch positions

2

Connection to SmartWire-DT

No

Equipment heat dissipation, current-dependent Pvid

0 W

Heat dissipation capacity Pdiss

0 W

Heat dissipation per pole, current-dependent Pvid

0 W

Rated operational current for specified heat dissipation (In)

0 A

Static heat dissipation, non-current-dependent Pvs

0 W

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation

Please enquire

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

10.4 Clearances and creepage distances

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

10.10 Temperature rise

Not applicable.

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Document Links

Datasheet