Q25LTR-BL/WB

ILLUMINATED PUSH-BUTTON

Trade Price

£20.95

Per

1

Unit

EACH

Pack Quantity

1

Q25LTR-BL/WB

Information

Eaton Moeller® series RMQ16 Illuminated pushbutton actuator, blue, maintained, +filament lamp 24V Q25LTR-BL/WB

Technical Specifications

Product Length/Depth

59 mm

Product Height

25 mm

Product Width

25 mm

Product Weight

0.011 kg

Certifications

CE

IEC/EN 60947

UL File No.: E29184

CSA Class No.: 3211-03

CSA-C22.2 No. 14-05

CSA File No.: 46552

CSA

UL Category Control No.: NKCR

IEC/EN 60947-5

UL 508

UL

Bezel color

Black

Bezel material

Plastic

Design

Flat

Fitted with:

Filament bulb (24 V)

Inscription

Blank

Degree of protection

NEMA 1

IP65

Degree of protection (front side)

NEMA 1

IP65

Lifespan, mechanical

30,000,000 Operations

Opening diameter

16 mm

Operating frequency

1800 Operations/h

Overvoltage category

III

Pollution degree

3

Product category

RMQ16

Rated impulse withstand voltage (Uimp)

800 V AC

Size

Front dimensions: 25 x 25 mm

Suitable for

Illumination

Terminal capacity

0.5 - 1.0 mm²

Terminal size

2.8 x 0.8 mm to DIN 46247 and IEC 60760, Fast-on connectors

2.8 x 0.8 mm to DIN 46244, Blade terminal

Type

Illuminated pushbutton actuator

Mounting position

As required

Shock resistance

40 g, Mechanical, According to IEC/EN 60068-2-27, Sinusoidal shock 11 ms

Mechanical, According to IEC/EN 60068-2-27

Ambient operating temperature - min

-25 °C

Ambient operating temperature - max

60 °C

Ambient operating temperature (enclosed) - min

-25 °C

Ambient operating temperature (enclosed) - max

40 °C

Climatic proofing

Damp heat, constant, to IEC 60068-2-78

Damp heat, cyclic, to IEC 60068-2-30

Rated insulation voltage (Ui)

250 V

Rated operational voltage (Ue) at AC - max

24 V

Actuating force

4 N

Actuator color

Blue

Actuator function

Switching function latching

Maintained

Connection to SmartWire-DT

No

Equipment heat dissipation, current-dependent Pvid

0 W

Heat dissipation capacity Pdiss

0 W

Heat dissipation per pole, current-dependent Pvid

0 W

Rated operational current for specified heat dissipation (In)

0 A

Static heat dissipation, non-current-dependent Pvs

1 W

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation

Please enquire

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

10.4 Clearances and creepage distances

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Document Links

Datasheet